A periodic check of the pilot and burner 

fl

 ames should 

be made. Check after the 

fi

 re has been on for at least 

30 minutes. The pilot 

fl

 ame must cover the tip of the 

thermocouple probe.
The main burner 

fl

 ame 

pattern will vary from 
appliance to appliance 
depending on the type of 
installation and climatic 
conditions.

The appliance area must 
always be kept clear and 
free from combustible 
materials, gasoline and 
other 

fl

 ammable vapors 

and liquids.
Inspect the vent terminal 
outdoors regularly to make 
sure that dirt, snow, insects, 
leaves, shrubs, trees do not 
obstruct it.
Examine the whole vent 
system regularly. We 
recommend annually.

Batteries

Low battery signal: page 33.

Thermocouple 
  probe must be 
    in flame

Correct fl ame appearance

With Logs

With Coals

With Rocks

Valve

Switch

ON

OFF

—   

O

 

All appliances use four 1.5V AA alkaline batteries for 
remote control receivers and the handset uses a 9V 
alkaline battery.
Batteries are accessible by opening the bottom access 
panel and removing the lid of the remote control 
receiver.
Batteries should last one to two seasons, depending on 
usage. Removing batteries in the off season will extend 
battery life.

Manual On/Off Switch

In cases where you want to turn off your 

fi

 replace 

and cannot do it with the remote control handset 
(misplaced, lost, dead batteries, etc.) or if you need to 
replace the receiver’s batteries, you can turn off the 
appliance with the manual switch located on the right 
hand side of the valve.

If you are planning not to use your 

fi

 replace for a 

prolonged period of time, remove the battery from the 
remote handset and turn off the gas valve using the 
manual ON/OFF switch.

Servicing

If your appliance require any attention, contact your 
supplier quoting the model number. It will be helpful if 
the appliance serial number can also be quoted. This 
is on the rating plate, which is on a chained, plate 
accessible by opening the bottom access panel.
The repair parts are shown in the separate repair 
parts lea

fl

 et. Please always quote part number and 

description when requesting spare parts.

CAUTION

DO NOT USE

 a screwdriver or other metallic object 

to remove the batteries from the receiver or the 
handset! This could cause a short circuit to the 
receiver.

CAUTION

To avoid short-circuit to the receiver, position the 

antenna

 so that it 

DOES NOT TOUCH the ignition 

wire.

Содержание 530ILN

Страница 1: ...r market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This ap pliance is not conve...

Страница 2: ...ould you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation m...

Страница 3: ...r Restrictors Installation 19 Gas Supply Installation 20 Aeration Setting Check 21 Ceramic Walls Installation logs and coals only 21 Ceramic Logs Installation 22 Ceramic Coals Installation 23 Ceramic...

Страница 4: ...OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation Due to the high temperature the appliance s...

Страница 5: ...ling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professional...

Страница 6: ...facturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirement...

Страница 7: ...t Max Btu h 20 500 19 000 Input Min Btu h 6 500 12 500 Manifold pressure in w c 3 5 3 9 10 3 10 7 Min Supply pressure in w c 5 11 Max Supply pressure in w c 10 5 14 Front Trims Various fronts are avai...

Страница 8: ...atings table on the previous page The supply connection is 3 8 inch NPT female located at the left side of the control valve The opening for the gas supply line is at the rear left corner of the appli...

Страница 9: ...clearance to center line of meter regulator assembly located within 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply i...

Страница 10: ...of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length 835TG Terminal Guard is required with 551DVK if terminating within 7 0 of grade o...

Страница 11: ...red with 551DVK if terminating within 7 0 of grade or where accessible 14 36 cm max combustible wall Approved side wall termination Approved through wall shield thimble 530 engine Use 835TG vent guard...

Страница 12: ...the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two no 6 thread cutting screws supplied Through the wall details If the wall has combustible materi...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear adapter 2 x...

Страница 15: ...r 2 Place the appliance in its proper location 3 Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position 4...

Страница 16: ...horizontal run as shown on page 14 in this manual 5 Fit the termination kit and flashing if required to the exterior of the chimney 6 Secure the appliance to the floor or wall if necessary Vertical T...

Страница 17: ...r inner vent collar and seal by unscrewing 8 screws 4 To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar 5 Position the inner collar and seal verticall...

Страница 18: ...the adapter to the outer collar with two no 6 thread cutting screws supplied Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top or...

Страница 19: ...on is optimal for each type of installation To fit the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under the screw heads and tighten the ce...

Страница 20: ...hut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the g...

Страница 21: ...en side For ceramic walls installation for 530IR engine see Ceramic Rocks Installation section in this manual At this point you can install the 567FGP Top Grille if used logs or rock version only sold...

Страница 22: ...he base log 6 4 5 1 2 3 Burner SIDE VIEW Back Brick Burner bracket Rest the base log behind the burner on its bracket flange BASE LOG Firebox supports 1a 5 Locate the left side log on the ceramic pin...

Страница 23: ...Place the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal 1 2 4 5 3 1a Burner SIDE VIEW Back Brick Burner bracket...

Страница 24: ...rille sold separately fit it now See instructions supplied with the grille 3 Place the rear panel on the rear support as indicated Hold in place and go to next step 4 Place the left and then the right...

Страница 25: ...e 4 Identify the rocks L and R Those rocks don t have any peg or hole Install those rocks as indicated at the left and right of the rock pile positioning them so that the arrows underneath point to th...

Страница 26: ...es to bed in the window seal Remote Control Initial Set up The receiver and the handset of the remote control system must be initially synchronized before the first use 1 Insert alkaline batteries in...

Страница 27: ...ation may result in black carbon forming and dropping into the firebox Packing Contents 1 Wall Bracket A 2 Screws B 1 Screw C 2 Wall Anchor D 1 Spacer E detach before assembly 1 Wall Bracket F Switch...

Страница 28: ...ing loaded bolts securing the bottom of the window 3 Carefully lift the window Keep the window and bolts in a safe place To refit the window 1 Place the window centrally against the engine unit restin...

Страница 29: ...ne to two seasons depending on usage Removing batteries in the off season will extend battery life Manual On Off Switch In cases where you want to turn off your fireplace and cannot do it with the rem...

Страница 30: ...tor turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and...

Страница 31: ...pressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in...

Страница 32: ...efore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go...

Страница 33: ...is no transmission from the handset to the receiver within a 6 hour period the appliance will go to Standby pilot mode Handset Receiver Match The remote control handset and receiver are programmed to...

Страница 34: ...QJ QHDU WKH RRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG V...

Страница 35: ...35 35 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram...

Страница 36: ...36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 TM CFAA3 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA G...

Страница 37: ...B SV4B Flat Roof Flashing 46DVA FF TF 4F SV4F 559FSK Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM Storm Collar 46DVA SC 4DT SC TM SC SV4AC Decorative...

Страница 38: ...on for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not...

Страница 39: ...K913 40 Window support 320B399 41 Switch bracket 4001070 41a Switch with cable 4001036 41b Cable interruptor receiver 4001035 42 Valve to main burner pipe connector 220K891 42a Interruptor block 40010...

Страница 40: ...40 40 1 2 4 5 6 7 8 9 10 11 12 13 14 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 38 39 40 41 42 43 44 43a 45 46 47 48 42a 41a 41b NG LPG Replacement Parts 44a 37...

Страница 41: ...41 41 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Replacement Parts 63 64 65 66 68 72 70 73 71 74 75 76 77 78 79 80 69 67 For 530IRN P only For 530ILN P and ICN P...

Страница 42: ...G natural gas LPG propane Serial No Fuel Bed Logs Rocks Coals Front code description e g 550CAP Classic Arch Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone...

Страница 43: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: