Valor 1800KNGK Скачать руководство пользователя страница 3

 Remove Burner Module

This section is only required if the appliance has been 

installed and wall 

fi

 nish has been applied. If not, the 

steps in the next section, “Replace the Minimum Rate 

Bypass Screw” , may be carried out through the access 

hole in the appliance’s front panel, without removing the 

burner module.

1. Con

fi

 rm gas supply is o

  and disconnect the fuel line 

from the valve.

2.  Remove 10 screws from the module plate as indi-

cated.

3.  Lift the burner module up while rotating it towards 

you, so the valve and all connections 

fi

 t through the 

opening.

Caution

Be careful not to damage any of the components 

beneath the module plate.

Replace Pilot Injector

1.  Remove pilot shield (2 screws).

2.  Remove the pilot hood by pulling out one side of the 

U-clip and pulling up on the hood. (The U-clip 

should not be removed)

3.  Unscrew the pilot injector using an Allen key. Dis-

card the old pilot injector.

4.  Replace with the appropriate pilot injector—see 

Speci

fi

 cations table on page 1 (the pilot injector 

number is stamped on the barrel). Screw in the new 

injector.

5. Re

fi

 t the pilot hood by pushing down on it (it is 

keyed to only 

fi

 t in one orientation). Ensure that it 

snaps into position.

6.  Replace the pilot shield (2 screws).

Pilot hood

U-clip

Access hole

3

Содержание 1800KNGK

Страница 1: ...d to set the manifold pressure 1800KNGK 1800KPGK Gas Conversion Kit Use with Valor L3 1800K Heater Models ONLY INSTALLATION MANUAL L3 Series 4008258 01 2020 Miles Industries Ltd Kit Contents 1 Pilot i...

Страница 2: ...ng a 7 16 socket wrench with an extension unscrew and remove the main burner injector from inside the injector block 2 Replace the old injector with the new injector from the kit using the socket wren...

Страница 3: ...tions fit through the opening Caution Be careful not to damage any of the components beneath the module plate Replace Pilot Injector 1 Remove pilot shield 2 screws 2 Remove the pilot hood by pulling o...

Страница 4: ...iquid detergent or soap solution to all connection joints that were taken apart and reassembled Bubbles forming indicate a gas leak Bypass screw Valve WARNING NEVER use an open flame to check for leak...

Страница 5: ...eration Instructions 2 Fit the label This appliance was converted on by near the data label fitted in 1 3 Fit the label This control has been converted on the left hand side of the appliance near the...

Страница 6: ...nversion de gaz 1800KNGK 1800KPGK Utilisez avec les foyers Valor L3 1800K SEULEMENT GUIDE D INSTALLATION S rie L3 Contenu du kit 1 Injecteur de veilleuse 1 Injecteur de br leur 1 Vis d indice minimum...

Страница 7: ...z l injecteur du br leur 1 l aide d une cl cliquet avec rallonge et une douille de 7 16 d vissez et enlevez l injecteur du br leur du bloc de l injecteur 2 Remplacez l injecteur par celui fourni avec...

Страница 8: ...a plaque du br leur 10 vis 3 En faisant tr s attention soulevez la plaque en com man ant par l arri re et pivotez la vers le haut pour d gagez les pi ces qui y sont attach es en dessous Remplacez l in...

Страница 9: ...une solution savonneuse sur tous les rac cords La formation de bulles indique une fuite de gaz R glez et v rifiez la pression d admission 1 Fixez un manom tre la connexion de v rification de pression...

Страница 10: ...on tel qu indiqu dans le Guide d installation du foyer R glez l obturateur d air Une fois le lit de combustion install r glez l obturation 1 Rep rez le levier d a ration derri re la paroi avant de l a...

Отзывы: