We recommend having your 

fi

 replace inspected before initial use, and serviced at least once per year by a 

quali

fi

 ed service technician. Contact your dealer quoting the model serial number, if possible. It will be helpful if 

the 

fi

 replace’s  serial number can also be quoted. These numbers are on the information card (see page 7). 

A list of replacement parts is included in your 

fi

 replace Installation Manual. When requesting spare parts please 

quote the part number and description to ensure the correct part is ordered.

 Annual Inspection

To ensure the optimal performance and safety of your 

fi

 replace, contact your dealer to have a quali

fi

 ed 

technician review and verify the list below at least once every year.

Safe Operation List: 

to be performed by a quali

fi

 ed technician only.

 

Inspect and operate the pressure relief mecha-

nism to verify relief mechanisms are free from 

obstruction to operate. See 

"Cleaning your 

fi

 replace"

 on page 13.

 

Clean glass window with a suitable 

fi

 replace 

glass cleaner. Abrasive cleaners must not be 

used. Be careful not to scratch the glass when 

cleaning. See 

"Cleaning your 

fi

 replace"

 on page 

13.

 

Inspect the operation of the 

fl

 ame safety sys-

tem Pilot or Flame recti

fi

 cation device.

 

Inspect and ensure the lighting of the main 

burner occurs within 4 seconds of the main 

gas valve opening. Visual inspection should 

match that outlined in the appliance instruc-

tion manual. Inspect primary air openings for 

blockage. See 

"Checking pilot and burner 

fl

 ames"

 

on page 17.

 

Inspect condition of vent and vent terminal for 

sooting or obstruction and correct if present.

 

Vacuum and clean any excess debris in the 

fi

 rebox that is not supposed to be there.

 

Test and measure the 

fl

 ame failure response 

time of the 

fl

 ame safety system. It must de-

energize the safety shut-o

  in less than 

30 seconds.

 

Check all accessible gas-carrying tubes, con-

nections, pipes and other components for 

leaks. See 

Set up Gas Supply

 section of the 

fi

 replace Installation Manual.

Annual service and maintenance

Caution

Label all wires prior to disconnection when 

servicing controls. Wiring errors can cause 

improper and dangerous operation.
Verify proper operation after servicing.

Содержание 1700KN

Страница 1: ...or s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or t...

Страница 2: ...market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert...

Страница 3: ..._ ________________________________________________ Please ask your installer for these details if they are not already provided or see page 7 Welcome to Valor Contents Safety and your fireplace 4 Chil...

Страница 4: ...he fireplace heats Although safe they may reach temperatures in excess of 200 F depending on elevation of the shelf Do not place anything on it Some materials or items although safe may dis color shri...

Страница 5: ...n under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water WARNING Do not operat...

Страница 6: ...rvised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individ...

Страница 7: ...heat from the pilot flame If the probe is cool the device will prevent any gas flow unless manually lighting the pilot See the full Fireplace and Lighting Information card attached to the fireplace or...

Страница 8: ...et OPTIONAL Parts of your fireplace Here are the major components of your installed fireplace with the protective barrier installed Your individual fireplace may appear differently depending on your i...

Страница 9: ...r fireplace OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear...

Страница 10: ...ace will not turn on unexpectedly On gas valve turn dial from ON position to MAN position as shown Turning dial to MAN will ensures that main burner cannot come on The pilot will remain on if lit Alte...

Страница 11: ...switch no tools required and withdraw the battery holder straight out from the wall it is attached to the plate Replacing batteries WARNING Do not attempt to access the batteries while the fireplace i...

Страница 12: ...glass cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Fla...

Страница 13: ...lifting and unhooking them Lift the plinth to remove it 3 1700K L2 and 1800K L3 models only Remove the plinth support bracket Remove plinth Remove side doors 4 Locate the levers on each side of the wi...

Страница 14: ...y Rutland Turtle Wax Do not clean the glass while it is hot Always securely replace the windows and the bar rier screen before lighting see next page If broken glass panes may only be replaced as a co...

Страница 15: ...ARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe operation Double check that t...

Страница 16: ...800K L3 models only Reinstall the plinth support bracket hooking it up to the sti ener bracket located below the window as shown Plinth support bracket Sti ener bracket 8 Reinstall the plinth and side...

Страница 17: ...is not obstructed by snow trees bushes leaves or other objects We recommend at least an annual inspection Checking pilot and burner flames Pilot flame Thermocouple probe must be in flame Note The heig...

Страница 18: ...e Murano Glass kit Pilot Light Pilot Light Pilot Light Rock Shale kit Birch Log kit Pilot Light Pilot Light Pilot Light Typical flame appearance L1 See Thru Driftwood log kit Splitwood kit Decorative...

Страница 19: ...color of your flames can vary depending on fuel type fuel quality and mixture altitude and aeration adjustment at or after installation The photos of typical flame appearance are for illustrative pur...

Страница 20: ...s in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I hear popping or snapping noises As...

Страница 21: ...field service Please contact your dealer see page 3 or visit valorfireplaces com contact for a list of dealers near you Who can service my fireplace We recommend having your fireplace serviced before...

Страница 22: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Страница 23: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Страница 24: ...ncluded Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco Mode F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Press and...

Страница 25: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 26: ...r only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light t...

Страница 27: ...anual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset temperature displays brie y followed...

Страница 28: ...OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes ash 4 To select minutes press or 5 To con rm press Not...

Страница 29: ...0 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit Low Battery Receiver With low batter...

Страница 30: ...ilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery symbol Permanent Battery icon ashes o...

Страница 31: ...ss and hold large flame button to gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can tur...

Страница 32: ...32 Notes...

Отзывы: