Valor 1600IN Скачать руководство пользователя страница 29

29

2

4

6

8

10

12

14

16

18

20

VERTICAL

 RISE (ft)

HORIZONTAL RUN (ft)

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

0

4 x 90º ELBOWS MAXIMUM 
(or equivalent)

Position #5

Example 1

NO INSTALLATION

Position #4

Position #3

Position #2

Position #1

Allowable Co-Axial Vent Con

fi

 gurations 

with restrictor positions

V2

V1

V3

H2

H1

Minimum 12” 
pipe section

45° elbow take-off
supplied with unit

1” min.

all around

vertical pipe

3” min.

above top of

horizontal pipe

1” min. around
bottom & sides 
of horizontal pipe

12” minimum 
vert pipe rise

How to Read the Venting Chart

The chart below applies to co-axial roof or wall 
termination.
1.  Minimum 12 inch vertical pipe section required 

within vent system either right off unit or down-
stream after horizontal run. 

2.  The total length of the vent pipe cannot exceed 

40 feet.

3.  The minimum vertical height with roof termination 

is 6 feet.

4.  Any combination of rise and run can be used as 

long as they are within the allowable limits shown 
on the chart below.

5.  A maximum of 4 x 90 degrees elbows—or 

equivalent (2 x 45 degrees = 90 degrees)—can 

be used. Excludes the 45 degrees take-off elbow 
shipped with the appliance.

6.  Each 90 degrees elbow installed on the horizontal 

plane is equivalent to a 3 feet horizontal pipe; 
therefore, 3 feet must be subtracted from allowable 
horizontal run. (45 degrees elbow is equivalent to 
18 inches horizontal pipe.)

7.  All horizontal pipe runs must be graded 1/4 inch per 

foot upwards in the direction of the exhaust 

fl

 ow. 

The 

fi

 nal pipe length, when terminating through the 

wall may be graded downwards slightly to prevent 
water migration.

8.  A restrictor adjustment is required for most 

installations having a vertical rise—see next 
section. 

Note:

 The restrictor is shipped installed at the 

exhaust exit of the 

fi

 rebox.

Co-axial Venting

 Venting Chart

Example 1
V Value = V1 (3’) + V2 (2’) + V3 (1’)= 6’
H Value = H1 (0’) + H2 (3’) = 3’
Restrictor position # 2 required

 NO INSTALLATION

QUALIFIED 
INSTALLER

Содержание 1600IN

Страница 1: ...sponible en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is...

Страница 2: ...M 43 Install Decorative Glass Set 1500DGS 45 Install Rocks Shale Set 1514RSS 47 Refit Window 49 Install Remote Battery and Wall Switch Kit RBWSK required 50 Set up Remote Control 52 Check Operation 52...

Страница 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Страница 4: ...hysical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk i...

Страница 5: ...technical appliance that must be installed by a qualified dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally insta...

Страница 6: ...s have had good results from the products listed below We cannot however guarantee the results of these products Brasso Polish Plus by Kelkem Cook Top Clean Creme by Elco White Off by Rutland Turtle W...

Страница 7: ...or glass particles in the railing before installing the window 2 Push the top of the window frame against the firebox Owner s Information 3 While you hold it pull the side levers back into the window...

Страница 8: ...en with the top levers up push the screen against the fireplace Rotate the levers down to hook them up to the trim and slide them inwards to secure them 7 Verify that the screen is properly hooked to...

Страница 9: ...card is attached under the plinth To access the card remove the barrier screen side doors and the plinth Grab the card and pull it out There is important information on both sides of the card Servici...

Страница 10: ...wing methods to ensure that your fireplace will not turn on when you don t want it on First ensure your fireplace is turned off including the pilot and cold BEFORE going ahead Turn the dial on the gas...

Страница 11: ...nfirm the ignition is in process Once pilot ignition is confirmed there is main gas flow After main burner ignition the handset will automatically go into manual MAN control mode Press OFF button When...

Страница 12: ...he hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode...

Страница 13: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERATURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Te...

Страница 14: ...TIMER moon while the time flashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minu...

Страница 15: ...hange in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appli ance will continue to wo...

Страница 16: ...ies 1270RBK Remote Blower Kit 1506DRK Additional Rock Kit for Long Beach Drift Wood Kit Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products f...

Страница 17: ...ton red dot on remote handset to shut off the appliance including pilot flame Spark Pilot Fig 3 Fig 1 Fig 2 1 OFF FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions e...

Страница 18: ...d a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions sh...

Страница 19: ...ded with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list a...

Страница 20: ...to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 or the Natural Gas and Propane Installation Code CAN CGA B149 Only qualified licensed or trained personnel...

Страница 21: ...safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other items sensitive to heat around the fireplace WARNING H...

Страница 22: ...nter of vent Heat shield required for side vent outlet applications Valve access side 51 1 4 1302 mm 18 1 2 470 mm 3 76 mm 9 1 4 235 mm 18 1 2 470 mm 2 3 4 70 mm 5 1 2 140 mm 33 1 8 841 mm 32 9 16 828...

Страница 23: ...rojection from Face of Cement Board Mantel Height from Bottom of Unit Fireplace Opening Fireplace Opening Ceiling 24 Min to Ceiling 44 42 40 38 33 23 7 8 9 3 8 4 minimum to combustible or non combusti...

Страница 24: ...24 39 11 16 Fireplace Opening Wall Min 4 to wall or combustible Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Mantel Hearth Clearances QUALIFIED INSTALLER...

Страница 25: ...finish NON COMBUSTIBLE MATERIALS ONLY READ INSTRUCTIONS MAT RIAUX INCOMBUSTIBLES SEULEMENT CONSULTEZ LE GUIDE D INSTALLATION Min 53 1346 mm 40 1016 mm Min 44 1 2 1130 mm Min 20 1 2 521 mm 14 3 4 375 m...

Страница 26: ...g other brands and in general are slightly bigger Minimum 12 inches vertical pipe section required within vent system either right off unit or downstream after horizontal run Refer to venting chart on...

Страница 27: ...up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Combustible Walls Ceil...

Страница 28: ...MBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION PIPE LENGTH 90 ELBOW 90 ELBOW Co axial...

Страница 29: ...t 4 Any combination of rise and run can be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equivalent 2 x 45 degrees 90 degrees ca...

Страница 30: ...no vertical rise The level of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based...

Страница 31: ...n 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet to any other appl...

Страница 32: ...o 11 12 3 25 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 Overhang should not extend beyond vent if within 48 of termination cap Horizontal overhang Vertical wall Min 24 unvented soffit Min 36 vented s...

Страница 33: ...fuel burning fireplace and chimney The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Requires a Co Axial to Co Linear appliance Adapter Rules for C...

Страница 34: ...and type of the wall finish around the firebox opening What accessories trim etc will be installed with this fireplace The venting configuration 2 Unpack the appliance removing all items packed inside...

Страница 35: ...d 1 Remove the side outlet collar 6 screws 2 Swivel the collar and install as a top outlet 6 screws Fit the appliance into framing 1 Remove the 4 screws retaining the engine to its pallet 2 Taking gre...

Страница 36: ...e to differential expansion of materials Pre drill cement board with oversized holes and do not over tighten screws to avoid cracking due to heat expansion Standard gypsum wall board may be used beyon...

Страница 37: ...Below are some tips on how to best avoid any cracking Allow materials to dry thoroughly before finishing the wall Cement board has the ability to absorb up to 30 percent of its weight in water and ma...

Страница 38: ...o the action of all gas constituents including LP gas Sealant should be ap plied lightly to male threads to ensure excess sealant does not enter gas lines Installation Left side view Valve access side...

Страница 39: ...for leaks by applying a liquid detergent or soap so lution to all joints Bubbles forming indicate a gas leak Never use an open flame to check for leaks Correct any leak detected immediately The press...

Страница 40: ...he upper part of the side panel 4 Repeat with the other side panel Glass panels The glass panels must first be fitted with the anchor brackets included in the carton The top panel is made of ceramic a...

Страница 41: ...e burner as indicated The openings in the platform should be underneath Push the platform as far back as possible to maximize the air gap behind the burner 2 Fill a small container with the equivalent...

Страница 42: ...ramics is shown from the valve access side of the appliance 1 Place the rear left log as indicated 2 Place the right log as indicated 3 Place the front left log as indicated 4 The rear log has two pin...

Страница 43: ...Decorative Glass Murano kit which contains 1 bag clear 1 2 fireglass 1 glass platform Installation Carefully unpack the kit 1 Install the steel platform around the burner as indicated The openings in...

Страница 44: ...r back as possible to maximize the air gap behind the burner 3 Fill a small container with approximately 3 cups 750 ml of mixed fire glass 4 Carefully spread the fireglass on the surface of burner pat...

Страница 45: ...o disengage it from the orifice and lift it out of the firebox 3 Remove the two platform supports 2 screws each flip them upside down and secure them back with the same screws 4 Re install the burner...

Страница 46: ...glass installed top view 7 Carefully spread the fireglass in the tray and on the burner Do not overfill the burner to avoid blocking the burner ports Ideally one layer of fireglass on the burner is su...

Страница 47: ...as possible to maximize the air gap behind the burner Rocks Shale Twigs 1 Place three rocks on the burner one at each end and one in the middle as indicated The rocks should not sit on top of the bur...

Страница 48: ...y over the burner edge 4 Add the twigs to the rocks placing them as shown Note The position of the twigs are specific to obtain the best flame pattern Note The acceptable variations are only for rocks...

Страница 49: ...ttom support railing Verify that the levers are hooked properly to the window tabs then Pull out the top of the window and release it to insure the springs return it Ensure the window is sealed before...

Страница 50: ...n position with Velcro bands 1 Pull out the receiver from its location to connect the battery holder and wall switch 2 Feed the white connector end of the harness assembly through side holes in firepl...

Страница 51: ...battery cover assembly 12 Position battery holder to rear face and secure together with cable tie note clearance is required for battery snap connection 13 Make the snap connection load 4 AA alkaline...

Страница 52: ...ion will cause the flames to appear more transparent and blue showing more ceramic effects glow Decreasing aeration will cause the flames to appear more yellow or orange showing less ceramic effects g...

Страница 53: ...his holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder to the wall find a con...

Страница 54: ...54 Wiring Diagram Wall Switch Kit GV60 Wiring Diagram Remote Battery Holder 4 AA Batteries 5 pin connector 9 Volt connector QUALIFIED INSTALLER...

Страница 55: ...M CFAA3 95090390 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL6 TM 4CAA6 4DCAB336 1156CLA5 6 9401064336 Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Fle...

Страница 56: ...SK 949606001 Masonry Flashing TF 4MF New Siding Flashing 658NSFK Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 9496...

Страница 57: ...r damage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances ii...

Страница 58: ...6a GV60 valve assembly NG 4003106 36b GV60 valve assembly LPG 4003118 37 Thermocouple interrupter 4001037 Code Description Part Number 38 Pipe s s flex 4000345 39 Handset wall holder 9000008 40 Handse...

Страница 59: ...brackets 2 4003033 74 Hot glass warning plate 4003093 75 Rocks Shale Set 1514RSS 76 LH twig 4001827 77 LH twig short 2 4001827S 78 RH twig 2 4001828 79 Grey Rock S4 A 6 4002338 80 Dark Grey Rock S4 A...

Страница 60: ...arts 13 1 2 3 4 7 9 9 7 10 11 12 12 8 8 6 5 73 74 14a 14b 15 17 18 19 23 24 25 26 27a 27b 28 29 30 31 32 33 34 36a 36b 35 38 37 41 40 42 39 45 43 44 3a 47 47a 47b 47c 47d 47e 47f 47g 47h 47i OWNER S I...

Страница 61: ...ng batteries 8 9 vent 3 8 Pilot ON OFF See Remote control Protection See Safety Remote Battery and Wall Switch Kit RBWSK installation 50 51 Remote control 11 15 52 automatic shut off 15 automatic turn...

Страница 62: ......

Страница 63: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Страница 64: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Отзывы: