5
BLOWER
BLOWER
JUNCTION BOX
WITHIN FIREPLACE
GND
3-PIN MOLEX
POWER CORD,
37” LONG
#4007877
POWER CORD ASSEMBLY
#4006350 SUPPLIED
SEPARATELY WITH FAN
CONTROL MODULE
NOTE - ALL WIRING IS SPECIFIC TO THIS KIT
AND SHOULD ONY BE REPLACED WITH
ORIGINAL EQUIPMENT WIRING FROM THE
MANUFACTURER.
FAN CONTROL MODULE
#4002530
(SUPPLIED SEPARATELY)
MOLEX
CONNECTORS
CIRCULATING FAN KIT
120 VAC, 60HZ, LESS THAN 1 AMP
MANUFACTURED BY
MILES INDUSTRIES LTD
NORTH VANCOUVER, CANADA
4007878-01
MODEL 1595CFKV2
THERMAL SWITCH
GROUND WIRE, BLOWER HOUSING
TO STUD ON MOUNTING PLATE
Apply label to
base next to fan
Junction box in
lower right corner
of liner box
Description
Part Numbers
Blower
4000537
Fan Mounting Bracket
4003053
3-pin Molex Power cord, 37” long
4007877
Thermal Switch
4003065
Cable, Switch to Motor, 10”
4003067
Ground cable, eyelet each end
4003068
Clamp Self Adhesive
4000536
Schematic label 1595CFKV2
4007878
6. Plug the fan power cord molex connector into the
control module marked “FAN”.
7. Plug the 3-prong power cord into receptacle at the
right into the fireplace case.
8. Use the self-adhesive wire clamp provided to secure
the cables to the base of the fireplace.
Apply label
Clean the area of sheet metal liner box base adjacent
to the fan, peel the self-adhesive backing from the label
provided with the kit and apply the label to the base.
Reassemble the appliance
Reassemble the unit in reverse order and continue
with the heater installation following the installation
instructions supplied with the heater.
Spares List