The unit is supplied with a stainless steel 

fl

 ex line to 

allow the appliance to be disconnected for service. 
The 

fl

 ex line is supplied loose to avoid damage during 

shipping. Connect the 

fl

 ex to the appliance valve as 

shown below. An individual shut-off valve (not supplied) 
is required on the supply line ahead of the 

fl

 ex 

connector.

Pressure test the supply line for leaks.

The appliance and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply 
piping system by closing its individual manual shut-off 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 
1/2 psig (3.5 kPa).

Failure to either disconnect or isolate the appliance 
during pressure testing may result in regulator or valve 
damages and void the warranty. Consult your dealer in 
case of damages.

Pressure Test Points

The minimum supply pressure is given in the section 

Specifi cations

 of this manual—page 19.

All piping and connections must be tested for leaks 
after installation or servicing. All leaks must be 
corrected immediately.

When testing for leaks:

•  Make sure that the appliance is turned off.
•  Open the manual shut-off valve.
•  Test for leaks by applying a liquid detergent or soap 

solution to all joints. Bubbles forming indicate a gas 
leak.

Never use an open 

fl

 ame to check for leaks.

Correct any leak detected immediately.

The pressure test tapping locations are shown in 
the 

fi

 gures on the right. An internal regulator within 

the valve controls the burner manifold pressure. The 
correct pressure range is shown in the table in section 

Specifi cations

 of this manual on page 19. The pressure 

check should be made with the burner alight and at its 
highest setting. See 

Lighting Instructions

 section for full 

operating details on page 16.

3/8” NPT male 

connector

Supplied loose

Valve Assembly

Pressure Testing

Control 

Valve

Manifold Test 

Pressure

Valve Inlet 

Pressure

Manifold Pressure 

Adjustment 

behind Plastic 

Cap

Installation

QUALIFIED 
INSTALLER

Содержание 1200EAN

Страница 1: ...appliance is a domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room This...

Страница 2: ...41 Synchronize Remote Control 42 Install Electrical Components for Decorative Lighting 43 Check Operation 44 Adjust Aeration if necessary NG units only 44 Install Window Skirt and Side Doors 44 Instal...

Страница 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Страница 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Страница 5: ...y installed by Dealer Name ________________________________ Phone Number _______________________________ Should you encounter an operational problem call your dealer immediately Do not try to repair t...

Страница 6: ...lers have had good results from the products listed below We cannot however guarantee the results of these products BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TURTL...

Страница 7: ...t hand pressure against the window frame sides to bed in the window seal 5 If the Hot Glass Warning plate has been removed from the front lower corner of the window reinstall it by sliding it between...

Страница 8: ...E changing the batteries turn off the valve WARNING DO NOT ATTEMPT TO CHANGE THE BATTER IES WHILE THE FIREPLACE IS STILL HOT Let the fireplace cool first before touching it Light fixture without glass...

Страница 9: ...na so that it DOES NOT TOUCH the ignition wire using the manual On Off switch see instructions next page The appliance uses four 1 5 V AA alkaline batteries for its remote control receiver and one 9 V...

Страница 10: ...Owner s Information Wall Switch optional Manual On Off Switch Thermostatic Remote Control this manual Please always quote the part number and description when requesting spare parts Operating Your Fir...

Страница 11: ...ame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 42 of this manual Set...

Страница 12: ...he hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode...

Страница 13: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback T...

Страница 14: ...flashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SE...

Страница 15: ...ed Replace with four 1 5 V alkaline batteries The remote control handset and receiver are program med to function together In case of a replacement of the handset or the receiver you will need to rese...

Страница 16: ...r If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWF...

Страница 17: ...d a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions sh...

Страница 18: ...ded with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list a...

Страница 19: ...efficiencies The installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 or the Natural Gas and Propane Installation Code CAN CGA B149 On...

Страница 20: ...ing the full width and depth of the appliance Remote Handset Wall Holder Wall Finish butted up to the edge of door plate Barrier Screen to prevent touching the hot glass 1 2 Insulation Board WARNING H...

Страница 21: ...op of cement board 50 to underside of header Electrical for ambient light only Electrical for ambient light only Zero Clearance to Stand Offs at Top Gas x x 6 5 8 dia Venting Center Line 6 6 46 3 4 of...

Страница 22: ...Cement Board 0 2 4 6 8 10 12 50 45 43 41 39 36 33 28 Mantel Projection from Face of Cement Board Combustible wall finish allowed above cement board Mantel Height from Bottom of Unit Fireplace Opening...

Страница 23: ...6 between edge of opening and wall Face of Finished Wall Note Right Side Clearances are the same Shading denotes allowable location for combustible mantel legs Combustible Sidewall Mantel Leg Top View...

Страница 24: ...han wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance WARNING SAFETY WARNING The Ventana is a very effective radiant heater Th...

Страница 25: ...engine This insulation board acts as a thermal break 2 Minimum hearth projection is determined by a combination of the height of the hearth above the surface of combustible floor or carpet and the di...

Страница 26: ...bustible floor 3 6 9 12 4 3 2 1 Surface of Combustible Floor or Carpet Bottom of fireplace Wood is Allowed Directly Below Fireplace Combustible Floor Allowed 2 616STK 617STK Leg Hearth Air Gap Surface...

Страница 27: ...Requirements Section Any surface directly in front of the unit which is at a height of less than 4 from the bottom of the unit must be non combustible See chart for minimum non combustible projection...

Страница 28: ...outer joints as a substitute to foil tape Ensure all the pipe joints have a minimum of 1 inch overlap Wall Thickness The appliance vent is suitable for penetrating a combustible wall assembly up to 8...

Страница 29: ...nd weatherproofed in such a manner as to Prevent rain water from entering the wall from the weather side by adequately caulking the outer vent plate to the exterior wall surface Prevent moisture insid...

Страница 30: ...terminating through the wall may be graded downwards slightly to prevent water migration 7 A restrictor is required for many installations see next section 2 4 6 8 10 12 14 16 18 20 Example 1 V Value...

Страница 31: ...e to the length of the vent pipe To install the restrictor 1 On an engine previously installed open the panels on each side of the window Remove the window skirt the window the logs the right and rear...

Страница 32: ...t may be opened 12 30 C Clearance to permanently closed window recommended to prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizon...

Страница 33: ...a co linear termination kit and flashing or a co linear to co axial adapter and either a high wind vertical vent terminal cap or a low profile vertical termination Firebox top zero clearance stand off...

Страница 34: ...struct the homeowner on the operation and maintenance of the fireplace 19 Install the window skirt 20 Install the control access doors 21 Install the andirons and fret if required 22 Finish the wall a...

Страница 35: ...page 6 Verify that you have all the components required for the installation including brick panels in separate carton surround doors fret andirons venting components and accessories electrical compo...

Страница 36: ...ng the panel out from under the firebox 2 Screw the appliance to the floor with 4 countersunk wood or cement screws not provided 3 Reinstall the overlay panel sliding it in the clips under the edge of...

Страница 37: ...tion is a 3 8 inch NPT male connector and is located on the left hand side of the firebox Use only new black iron or steel pipes or copper tubing if acceptable check local codes Note that in USA X cop...

Страница 38: ...case of damages Pressure Test Points The minimum supply pressure is given in the section Specifications of this manual page 19 All piping and connections must be tested for leaks after installation or...

Страница 39: ...the top panel over the top edge of the rear and side panels Leave the panel to balance there until right hand side panel is installed 5 Hold the right hand side panel at an angle and insert it totall...

Страница 40: ...k of middle log support Pins for Top Left and Right Logs Touches here Pins for Middle Left and Right Logs Middle Log position on pins at each end 2 Place the Middle Log on the pins of the middle log s...

Страница 41: ...Log on the left pin of the middle log with its wider end resting on the front log Place on pin with log projecting forward 5 Place the charred end of the Middle Right Log on the right pin of the midd...

Страница 42: ...between the glass and the frame as indicated Synchronize Remote Control The receiver and the handset of the remote control system must be initially synchronized before the first use 1 Insert alkaline...

Страница 43: ...junction box 6 In the junction box hardwire the harness to the electrical wire Refit the junction box cover Outside the firebox fit a cable clamp 7 Fit the cover plate to the wall not supplied Electri...

Страница 44: ...aeration will cause the flames to appear more transparent and blue showing more ceramic log glow Decreasing aeration will cause the flames to appear more yellow or orange showing less ceramic log glo...

Страница 45: ...t the temperature sensor located in the remote handset Packing Contents 1 Wall Bracket A 2 Screws B 1 Screw C 2 Wall Anchor D 1 Spacer E detach before assembly 1 Wall Bracket F Switch Plate Alternativ...

Страница 46: ...46 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram QUALIFIED INSTALLER...

Страница 47: ...95090390 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL6 TM 4CAA6 4DCAB336 1156CLA5 6 9401064336 Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible L...

Страница 48: ...A FF TF 4F SV4F 559FSK 949606001 Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 94960608 Dec...

Страница 49: ...rom other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass...

Страница 50: ...32 Valve to Burner Pipe Assembly 4001279X 33 Location Support Assembly 2 4001288X 34 Top Gasket 4001269 35 Bottom Gasket 4001363 36 Sealing Gasket 4001364 37 Side Gasket 2 4001268 Spare Parts Code De...

Страница 51: ...a Stone 4001325 c Inca Slab 4001326 d Black Slab 4001479 69 Overlay to cover front bottom FP 4001500AZ 70 LH Burner Support 4001511 71 RH Burner Support 4001512 72 Restrictor 4001222 73 Hot Glass Warn...

Страница 52: ...75 77 76 17 18 11 56 55 63 69 72 19a 19b Pilot Assy 20a to 27 28a 28b 31a 31b 33 Module Plate Gaskets 34 to 37 39 40 42 42a 43 59 60 61 62 38a 38b 44 71 72 47a 47b 48 49 50 51 52 53a 53b 54 64 65 67...

Страница 53: ...ion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model N...

Страница 54: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: