Burner.
Remove any deposits of soot or other foreign matter from the solid areas of the
burner with a dry soft brush. Be careful not to brush any particles into the open holes.
Remove any particles from the holes with a vacuum cleaner fitted with a soft brush
attachment.
Do not poke wire, etc. into the holes in the burner.
FUEL BED REFITTING
On ‘Aspect Glass’, ‘Fascination’ and ‘Tranquility’ models the fascia will have to be
removed to gain access to the ceramic fuel effect. The fascia is held in place by four
retaining plates at the back of the fascia. These slot into four retaining brackets on the
hotbox. To remove the fascia, hold the sides of the fascia and lift upward and forward.
The fascia should lift clear of the hotbox (See figure 7). The fascia can be replaced in
the reverse order.
The installer and owner guide for the ceramic fuel effect is separate from this guide.
The installer may have attached it to this guide or placed it inside. It is important that
the installer and owner guide for the ceramic fuel effect is followed correctly. If
replacing the ceramic fuel effect, where a new guide is supplied, follow the installer
and owner guide supplied with the replacement fuel effect.
Keep the replacement installer and owner guide with this owner guide for future
reference.
MAINTENANCE
Regular maintenance.
In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept
clear of any form of obstruction. It is possible that deposits of mortar or soot could fall
and accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least
every twelve months by a competent person (In the U.K, a CORGI registered
installer).
We recommend that all gas appliances and their flues, wherever situated, are
checked annually.
E
Page 51
©
Baxi Heating U.K. Limited 2008.
OWNER GUIDE