3.
Unscrew and remove the screw that
secures the slider arm assembly to the burner
(See figure 14).
4.
Each unit is flame tested before it leaves
the factory and as a result there may be slight
discolouration around the burner ports. Detach
the burner unit from the convection box by
removing two screws (See figure 15). Lift the
burner unit clear.
5.
It is important that the grommet supplied in
the loose parts pack is fitted to the hole in the
rear of the convection box (See
figure 16).
9.2 Fitting the foam seal.
There is a length of self
adhesive foam seal supplied
with the fire. This will need to be
fitted to the rear of the
convection box as shown in
figure 16. Cut the foam seal to
the required lengths. Be careful
not to stretch the seal when
measuring. Remove the
protective backing from the foam seal and fit this to the rear of the convection box
flange (See figure 16).
Page 26
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 16.
Figure 15.
Figure 14.
Содержание 963
Страница 7: ...1 IMAGES Page 7 Baxi Heating U K Limited 2010 INSTALLER GUIDE Petrus fascia Dream fascia...
Страница 21: ...Page 21 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 9 Pack one contents Continued on next page...
Страница 22: ...Page 22 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 9 Pack two contents...
Страница 49: ...IMAGES Page 49 Baxi Heating U K Limited 2010 OWNER GUIDE Petrus fascia Dream fascia...
Страница 64: ...Baxi Heating U K Limited 2010...