17
Connecting instructions for five-vein cable (three-phase appliances – 400/50/3):
A test start-up of the appliance is carried out by an appropriately trained
electrician who has also connected the machine so as to make sure that it is
properly connected (see the section on MAINTENANCE).
If the machine has been connected correctly, the mixer in the mixture-treating
cylinder will rotate anti - clockwise.
Production cylinder mixer, installed in appliances with built-in inverter, will rotate
in the correct direction regardless of the connecting position of either of the
phases.
After connecting the appliance to the electricity network, appropriately trained
electrician must also control the power consumption. The current must not
exceed the maximum allowed on the identification plate or sticker (see the
section GENERAL FEATURES AND SPECIFICATIONS).
6 OPERATING THE APPLIANCE
The user operates the appliance standing in front of appliance. This position
allows user to handle the control panel, the safety switch and the water flow
regulation valve (shower).
The appliance must be always under users control during operation.
The emergency stop switch is used to safely and securely switch of the
electronics. The electronics is switched off by pressing down the switch-off key
in the normal position and then depressing it. The switch will normally remain
down and must be pulled back up by hand to return to its normal position.The
shower is used for cleaning of the appliance.
EMERGENCY STOP SWITCH
WATER VALVE
CONTROL BOARD
WATER PIPE
(DRINKABLE WATER)
phase type color
L1 400 V ~ black
L2 400 V ~ brown
L3 400 V ~ grey
N neutral blue
PE ground yellow-green