INTRODUCTION

SAFETY

Safe and appropriate handling requires knowledge of the basic 
safety regulations, and of the intended use of the ventilation 
system. Read this manual before operating the ventilation unit. 
Retain the manual for later reference. If you lose the manual, it can 
be downloaded from our website.

This user manual contains all the information necessary for safe 
operation of the system. All persons who operate and maintain 
the ventilation system must follow the instructions provided in this 
manual. Furthermore, all local accident prevention regulations must 
be observed.

Installation

Installation and setup should be carried out only by qualified 
experts. Electrical installations and connections must be carried 
out only by an electrician and in compliance with local regulations. 

GUARANTEE

The guarantee and liability exclude damage resulting from:

• 

Inappropriate use of the ventilation system or the control unit

• 

Incorrect or inappropriate installation, setup or use

• 

Neglect of instructions concerning transportation, installation, 
use, or maintenance

• 

Structural or electronic modifications or changes made to the 
software

INTENDED USE

All Vallox ventilation units have been designed to provide 
appropriate and continuous ventilation so as to present no threat to 
health and to maintain structures in good condition.

IMPORTANT  

In order to ensure that the indoor air presents no harm to 
health and remains optimal also for the structures of the 
building, 

ventilation must be kept on without disruptions.

 It 

is recommended that ventilation be left turned on during long 
holidays also. This keeps the indoor air fresh and prevents humidity 
from condensing in the ventilation ducts and structures. It also 
reduces the risk of moisture damage.

DISPOSAL OF THE VENTILATION UNIT

Do not dispose of electronic devices with household waste. Follow 
local laws and regulations on safe and ecological disposal of the 
product.

 WARNING

The unit is not intended for 
use by children under 8 or by 
persons with reduced sensory, 
physical or mental capabilities, 
or whose lack of knowledge 
and experience do not ensure 
safe operation of the unit.

Such persons can use the 
unit under supervision, or by 
following the instructions of 
someone who is responsible for 
their safety.

Содержание Vallox TSK Multi 50 MV EH

Страница 1: ...EH Vallox TSK Multi 80 MV Vallox TSK Multi 80 MV EH Vallox TSK Multi 80 MV EHX Vallox 90 MV Vallox 90K MV Vallox 096 MV Vallox 110 MV Vallox 145 MV Vallox 245 MV Vallox 245 MV VKL MANUAL Document D37...

Страница 2: ...oncerning transportation installation use or maintenance Structural or electronic modifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide...

Страница 3: ...l Automatic summer winter damper Supply air filter G4 Extract air filter G4 Post heating radiator Safety switch Control panel Carbon dioxide sensor Humidity sensor 8 9 10 11 12 1 2 3 4 5 6 7 R model i...

Страница 4: ...lest fan icon indicates that the Away pro le is in use and the largest fan icon indicates that the Boost pro le is being used Droplet symbols indicate the relative humidity of air The symbols are One...

Страница 5: ...Indicates the fan speed If the automatic fan speed boost is turned on the set value is shown in brackets first followed by the actual fan speed Cell status Indicates the status of the ventilation unit...

Страница 6: ...ct air fan speed relative to the maximum speed Modifying and saving the pro le settings IMPORTANT The unit does not automatically save any settings not even those that are currently in use Unless save...

Страница 7: ...ed by pressing the temperature button on the pro le display Viewing temperature statistics 1 Select Settings Temperatures and sensors 2 Select OK 3 Select Statistics 4 A graph appears on the display s...

Страница 8: ...Statistics next to the sensor group you wish to view 2 A graph opens on the display showing the relative humidity of air and carbon dioxide levels recorded over the past 24 hours by the sensor with th...

Страница 9: ...aintenance section After replacing the lters enter the replacement date 1 Select Settings Filters 2 Select OK 3 Select Edit 4 Select Plus on the Filter replacement display The Last replaced field now...

Страница 10: ...K 3 Use the Plus and Minus buttons to set the Sleep time 4 Select OK TIP The MyVallox Control control panel automatically switches to the sleep mode when the pre set Sleep time has elapsed To reactiva...

Страница 11: ...to set the minutes 6 Select OK Selecting the 24 or 12 hour clock The 24 hour clock is used by default To use the 12 hour clock 1 Select Settings Time and date 2 Select OK 3 Select Right arrow until t...

Страница 12: ...The Away profile is used Boost The Boost profile is used Blank Do not change the profile NOTE If you change the pro le manually when the week clock is on the selected pro le will be active until the w...

Страница 13: ...to leave without saving the week program or the changes made to it 8 Once you have saved the week clock program select OK on the con rmation display Turning the Week clock off 1 Select Settings Week...

Страница 14: ...t home profile 5 Ensure that the Week clock is turned on 6 The weekly program has now been set USING THE UNIT TURNING THE UNIT OFF To turn the ventilation unit off 1 Select Settings Turn unit off 2 Se...

Отзывы: