background image

11

© Vallox Oy - All rights reserved

 

TECHNIC

AL SPECIFIC

ATIONS 

VALLOX TSK MULTI 80 MC

1  Supply air fan
2  Extract air fan
3  Post-heating radiator,  

electrical, 900W 

(behind the supply air 

fan) 

4  Heat recovery cell
5  Supply air filter F7
6  Supply air filter G4
7  Extract air filter G4

8 Automatic 

 

summer/winter damper

9  Safety switch
10  Adjusting the supply 

and extract air ratio

11  Adjusting the supply 

air temperature 

and summer/winter 

function

R model:

1.  Outdoor air to the unit
2.  Supply air to the apartment
3.  Extract air from the apartment to the unit
4.  Exhaust air out

L model:

1.   Extract air from the apartment to the unit
2.  Exhaust air out
3.  Outdoor air to the unit
4.    to the apartment

Main parts

Dimensions and duct outlets

1

8

7

6

2

4

5

3

11

9

10

R model in the figure.  

Dimensions are mirrored for the L-model

626

1026

View from above

Right side

Left side

1

1

2

3

3

4

293

200

96

96

96

231

231

96

200

Seen from behind

1

2

3

4

110

200

View from 

right

1

4

254

110

View from 

left

2

3

2

4

Elbow

Space required 

for installation: 

47mm

54

43

28

Water seal

Space required 

for installation: 

70mm

Total height with an elbow 321 mm 

Total height with the Vallox Silent Klick  

water seal is 336 mm 

SOUND VALUES

Sound power level in the supply air duct

 by octave band L

w

, dB

Sound power level in the extract air duct

 by octave band L

w

, dB

Adjustment position V / Air flow dm

3

/s

Adjustment position V / Air flow dm3/s

Adjustment position 

/ V

3

4

5

6

7

8

9

10

11.3

3

4

5

6

7

8

9

10

11.3

Air flow dm3/s

15.6

23.1

31.6

39.6

47.9

57.7

65.7

75.2

83.8

22.3

33.1

43.3

50.3

59.3

71.2

81.3

92.2

101

Medium 

frequency 

of the 

octave 

band Hz

63

43.2

43.3

55.8

52.4

54.3

56

57.4

60.4

60.4

*38.9

39.8

48.4

47.3

48.5

54.5

57.7

55

55.6

125

39.1

46.1

52.4

54.6

56.9

58.5

60.4

61.9

64.5

33.9

41.6

48

48.3

50.9

53.7

56.8

58.3

60.1

250

38.3

46

50.9

56.6

60.3

68

69.5

72

71.9

30.3

36.7

42.9

46.9

50.3

55.3

56.9

58.2

59.1

500

33.1

40.9

47.4

51.8

56.3

59.9

63.2

66.8

73

*21.8

27.1

34.3

37.5

42.9

45.9

48.9

52.3

55.2

1000

*27.9

36.2

42.5

47.1

51.8

56.5

59.7

62.9

66

*19.8

*25.5

32.1

35.7

40

44.1

47.5

49.9

53.1

2000

*19.7

30.1

38.3

43.6

48.9

53

56.2

59.3

62

*13.9

*16.4

*22.3

25.8

29.7

33.6

37

39.8

42.3

4000

*17.9

*20.0 *25.8

31.5

37.2

42.2

46.1

49.6

52.5

*18.0

*17.7

*17.8

*18.0

*18.8

*20.7 *23.9 *26.7

29.4

8000

*22.9 *23.0 *23.0 *23.2 *24.4

*27.3

30.8

34.9

38.5

*23.0 *23.0 *23.0 *23.0 *23.0

*23.1

*23.1

*23.2 *23.5

L

W

, dB 

L

WA

, dB(A)

45.9

50.8

58.8

60.6

64

69.6

71.5

74.2

76.6

*40.7

44.7

52

52.6

55.2

59.6

62.3

62.9

64.4

*35.0

42.6

48.8

53.4

57.9

63.2

66.1

69.1

72.2

*28.1

*32.7

38.9

41.6

45.7

49.8

52.7

54.8

57

Sound pressure level, in decibels (A) coming through the envelope from the room in which the unit is installed (10m

2

 sound absorption) 

Adjustment position V / air flow dm

3

/s (supply/extract)

Adjustment position 

/ V

3

4

5

6

7

8

9

10

11.3

Air flow dm

3

/s

15.1/19.5

23.4/27.8

32.3/36.8

39.3/43.1

47.4/52.1

57.0/61.7

66.1/70.4

74.8/79.2

84.0/88.1

L

pA

, dB (A)

*24.7

*28.9

34.4

37.4

42

45.9

49.5

51.2

53.5

Содержание TSK Multi 80 MC R

Страница 1: ...Manual MANUAL Low energy ventilation unit with heat recovery Document D2585 Valid from 15 1 2018 Updated 29 1 2018 Model TSK Multi 50 MC TSK Multi 80 MC Types 3603 3602...

Страница 2: ...upply and extract air ratio Adjusting the supply air temperature and summer winter function Vallox Simple Control control panel ordered separately 1 2 3 14 15 4 5 6 7 8 9 10 11 12 13 R model in the fi...

Страница 3: ...post heating is turned off and the heat recovery cell is bypassed when the outdoor temperature is above 14 C The heat recovery will be turned on when the outdoor temperature falls below 12 C In the AU...

Страница 4: ...r is turned clockwise the extract air flow is reduced The potentiometer for adjusting the supply and extract air flows Concealed installation of the fireplace switch optional MAINTENANCE REMINDER If a...

Страница 5: ...on unit maintenance FILTERS When the maintenance reminder becomes activated check the cleanliness of the filters and replace them if required The Vallox ventilation unit has three air filters Class G4...

Страница 6: ...OVERY CELL Check that the heat recovery cell D is clean roughly once a year when the filters are being replaced Clean by washing as required Pull the coarse filters including the frames out of the uni...

Страница 7: ...ass duct filter stand package out of the unit and turn to the right 3 Disconnect the cable of the bypass damper motor 4 Tilt the supply air fan to the right and push the connectors out of the way 5 Tu...

Страница 8: ...rotection class IP34 Post heating radiator Electric 900W Preheating radiator Additional heating radiator Fans Supply air Extract air 0 043 kW 0 32 A EC 0 043 kW 0 32 A EC Specific energy consumption S...

Страница 9: ...sition V Air flow dm3 s Adjustment position V 3 4 5 6 7 8 9 10 11 4 3 4 5 6 7 8 9 10 11 4 Air flow dm3 s 8 1 13 8 18 8 25 1 31 3 38 7 43 9 50 4 54 6 13 7 19 1 26 2 32 1 37 9 45 50 3 56 9 62 8 Medium f...

Страница 10: ...ting radiator Electric 900W Fans Supply air Extract air 0 071kW 0 5 A EC 0 071kW 0 5 A EC Specific energy consumption SEC in a cold climate in a temperate climate A B Operating efficiencies Annual eff...

Страница 11: ...Adjustment position V Air flow dm3 s Adjustment position V 3 4 5 6 7 8 9 10 11 3 3 4 5 6 7 8 9 10 11 3 Air flow dm3 s 15 6 23 1 31 6 39 6 47 9 57 7 65 7 75 2 83 8 22 3 33 1 43 3 50 3 59 3 71 2 81 3 92...

Страница 12: ...hood Cables BK black BN brown BU blue GN green GY grey WT white YE GN yellow green RD red 951155 951123 951153 951159 BU 1 BN 2 YEGN 9 951150 951152 BN 7 W T 8 GN 15 YE 16 RD 7 W T 8 BU 15 YE 16 BK 1...

Страница 13: ...inal connector GND S GND S MC VENTILATION UNIT Four terminal connector MV VENTILATION UNIT GND AN I RM I RM O E I LED E O PROGRAMMING CONNECTORS OF THE MOTHERBOARD CONTACT DATA GUARD FUNCTION NORMAL S...

Страница 14: ...RS 485 Common RH optional 946147 Nomak 2x2x0 5 0 5 0 10V LED G G0 Y1 Y2 DI1 A1 Y3 A2 Y4 U1 A B C S DI2 G0 Vallox Procontrol 949034 S LED S B term CONFIG Control signal S Cooker hood or boost switch 11...

Страница 15: ...ot cause any disturbance Such locations include storage premises and technical spaces Important The whole length of the outdoor air duct to the unit and exhaust air duct from the unit must be insulate...

Страница 16: ...ulti 80 MC 942211 13 Side sealing strip of the heat recovery cell 3356300 Vallox TSK Multi 50 MC 13 Side sealing strip of the heat recovery cell 3352600 Vallox TSK Multi 80 MC NO Part Product number 1...