© VALLOX • We reserve the right to make changes without prior notification
Autumn
• Wash or change the coarse filter and clean
or change the fine filter if needed. The
recommendation is approximately once a
year.
• Check that the heat recovery cell is clean.
• Check that the condensing water outlet is
not clogged.
Spring
• Wash or change the coarse filter and clean
or change the fine filter if needed.
• Clean the fan blades and the post-heating
unit if needed.
• Check that summer ventilation is in
operation.
VALLOX TSK Multi 50/80
THREE QUESTIONS ABOUT VENTILATION
3
1.
THREE QUESTIONS ABOUT VENTILATION
1.1. Why is air replaced in dwellings?
Good ventilation promotes healthy living for both residents and the building.
Air in a dwelling needs to
be replaced in order to remove humidity brought about by living as well as impurities
emanating from structures and human bodies. Impurities of indoor air include carbon
dioxide, formaldehyde, radon and other gases as well as dust.
Mechanical ventilation is needed in order to be able to adjust air circulation as needed by
the residents. In a tightly sealed house, air does not circulate sufficiently by natural means.
Even in a poorly sealed house air is only replaced because of differences between indoor
and outdoor air temperatures, or because of winds. This means that ventilation is dependent
on weather conditions and cannot be regulated.
It is especially important that humidity and carbon dioxide content of the indoor air stay at a
healthy level. Recommended humidity content of good indoor air is approximately 45%.
Humidity content is lower in winter and higher in summer and autumn. Dust mites thrive in
indoor air if humidity exceeds 50%, and if humidity stays at over 60% for a long time in
winter, water condenses in the cold structures of the house and mould starts to form.
The recommended maximum carbon dioxide content in good indoor air is circa 1,000 ppm.
1.2. What are the characteristics of adequate ventilation?
• Indoor air stays fresh in all the rooms of the dwelling, also in bedrooms during night.
Without adequate ventilation
, carbon dioxide content tends to rise high especially in
bedrooms.
• The bathroom and the sauna get dry quickly.
• During the heating season, the windows and other outer wall structures remain dry.
• Humidity in indoor air is not condensed in the ventilation ducts.
• Air is fresh in the toilet as well.
1.3. How much air is replaced?
For air to be clean to breathe, it has to be replaced with outdoor air
every two hours
.
In a new and a renovated house, air needs to be circulated continually, at least once an
hour, during the first year in order to remove harmful gases and structural humidity. In
buildings that are more than a year old and dry, ventilation can be regulated as needed.
Ventilation is boosted during for instance a sauna bath, clothes washing and cooking, and
reduced during very cold periods or when there is nobody at home. Carbon dioxide and
humidity sensors adjust ventilation in the rooms automatically as needed.
SEASONAL CALENDAR
NOTE!
For further details, see inner pages.
SEEN FROM ABOVE
3
SEEN FROM
THE LEFT SIDE
Left side
SEEN
FROM THE
RIGHT SIDE
3
4
4
2
2
2
1
1
1
3
4
Model L:
1. Extract air to the unit
2. Exhaust air outside
3. Outdoor air to the unit
4. Supply air to rooms
Model R:
1. Outdoor air to the unit
2. Supply air to rooms
3. Extract air to the unit
4. Exhaust air outside
4
SEEN FROM BEHIND
3
1
2
DUCT OUTLET OPTIONS, Vallox TSK Multi 50/80
Right side
Содержание TSK Multi 50 Series