Location of DIGIT SE
VALLOX DIGIT SE is mounted
in a place where temperature
does not fall below +10
°
C. A
ventilation unit without casing
has to be located in a place
where the operation is not
acoustically disturbing at the
greatest speeds; suitable places
are storerooms, utility rooms
and similar spaces. DIGIT SE
can also be located in a damp
room, but not in a washroom
next to a sauna bath.
Mounting
VALLOX DIGIT SE is mounted
on the wall using a wall moun-
ting plate as shown in the ad-
jacent picture. If needed the
mounting can be secured at the
lower end of the ventilation unit.
Wall structure
The mounting must be observed
in the wall structure. Prevent
mounting the ventilation unit on
an echoing hollow partition wall
and on a bedroom wall becau-
se of sound conduction.
Condensing water
A water seal is included in the
delivery. Through the piping
connected to this water seal,
the water condensing from ex-
tract air is led to a floor drain
(and not directly to the waste-
water drain). The drain must
not rise after the water seal.
The ventilation unit has to be
mounted horizontally, in order
for condensing water to flow
freely out of the ventilation unit.
NOTE!
If you mount the ventilation unit
above a hot water storage unit,
for instance, observe the con-
densing water draining and ex-
ternal wiring to the connection
box of the ventilation unit befo-
re mounting.
Example:
You may mount the condensing
water piping in advance and
attach the connection box besi-
de the ventilation unit.
VALLOX DIGIT SE / VKL
© VALLOX • We reserve the right to make changes without prior notification.
Vallox Oy 32200 Loimaa Puhelin (02) 763 6300 Telefax (02) 763 1539
www.vallox.com
LOCATION AND WALL MOUNTING
1.09.61F/28.8.8/PDF