MOUNTING INSTRUCTIONS

During mounting, the unit rises  
10 mm higher than the final height.

The lead-in of electric wires can be 
done from both sides of the unit.

Bottom edge 
of bracket

Bottom edge 
of bracket

Condensing water  
connection and water 
seal

ø7, 14 pc

Содержание 90K MC Series

Страница 1: ...90K MC R VALLOX 90K MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230V 50Hz 5 7A Degree of protection provided by enclosures IP34 Fans Extract...

Страница 2: ...n it is advisable to contact Vallox Maintenance Adjustment of the relationship between supply and extract air This feature may be useful when adjusting air flows at the valves during mounting After th...

Страница 3: ...s of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a coarse filter C By us...

Страница 4: ...maintenance e g in autumn before the beginning of the heating season make sure that the condensing water outlet L in the bottom tank is not clogged You can check it by pouring a little water in the t...

Страница 5: ...nd values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilation unit to extract air ducts by octave band LW dB ADJUSTMENT POSITION...

Страница 6: ...fety switch SNO Phase voltage to supply air fan SFN Zero voltage to supply air fan EFL Phase voltage to extract air fan EFN Zero voltage to extract air fan FSO Input to fireplace switch FSI Fireplace...

Страница 7: ...g a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain The pipe must not rise after the water seal The unit has to be mounted horizontal...

Страница 8: ...clude can vary depending on the sales area MOUNTING INSTRUCTIONS During mounting the unit rises 10 mm higher than the final height The lead in of electric wires can be done from both sides of the unit...

Страница 9: ...e The preset voltages are as follows 2 5 V 5 V 7 5 V and 10 V Note Do not set control voltage so low that the fan does not start circa 1 5 V Sample adjustment of air flows Basic ventilation is adjuste...

Страница 10: ...be a separate extract valve in the kitchen Basic extraction is not possible through the cooker hood when a VALLOX 90K MC unit is used The cooker hood is used for boosted smoke abatement An alternativ...

Страница 11: ...r edge of the covering door on the door of the ventilation unit VALLOX 90K MC Mounting of covering door brackets Lower edge of covering door 620 Fixing moulding A Glue the magnet tape C Screws 3 5 15...

Страница 12: ...12 Vallox 90K MC VALLOX We reserve the right to make changes without prior notice What the units include can vary depending on the sales area 1 09 351E 17 1 2019 PDF MOUNTING INSTRUCTIONS...