MOUNTING INSTRUCTIONS
Mounting
VALLOX 90K MC has to be mounted in a place where temperature
does not go below +10 °C.
Wall mounting
VALLOX 90K MC is mounted on the wall with a mounting plate as
shown in the adjacent figure.
Wall construction
Observe the wall construction during mounting. Avoid mounting the
unit on a hollow, echoing dividing wall and on a bedroom wall
because of sound conduction, or prevent sound conduction.
Condensing water
The delivery includes a water seal. By connecting a pipe to the
water seal the water condensing from extract air can be led to a
floor drain (not directly to the drain). The pipe must not rise after the
water seal. The unit has to be mounted horizontally level, so that
condensing water can get out of the unit.
Cooker hood mounting
The cooker hood is mounted at the bottom of the VALLOX 90K
MC unit with knurled-head nuts (A), included in the accessory bag
delivered with the unit. Open the cooker hood’s bottom plate, which
has the grease filter attached to it, lift the hood against the bottom of
the ventilation unit and fasten the hood with the knurled-head nuts.
Thread the connection wire (B) as shown in the figure, and use a wire
shield (C) if needed
Damper
Hood connection wire and
wire shield
Condensing water outlet
Condensing wire outlet port
Knurled-head nut, fastening of
hood