Observe in the figure:
1. Elbow.
2. Exit hole for the condensing water outlet.
Vallox 51K MV
In Vallox 51K MV, an elbow is mounted on the bottom pool between
the unit and the cooker hood. A condensing water tube is led from
the elbow e.g. into the siphon of the sink or to the floor drain. The
siphon must not be installed inside the cooker hood. Instead, it
must be installed in the condensing water tube so as to enable
maintenance measures. There are approx. 2 mm wide holes at the
rear of the bottom of the Vallox 51K MV ventilation unit marking the
position where the condensing water tube must be installed.
1. Install the elbow at the bottom of the ventilation unit without
the siphon (Figure 1). Install the siphon in the condensing water
tube before the drain or odour trap (Figure 2). The Vallox Silent
Klick siphon helps prevent noise disturbance caused by the
removal of condensing water.
2. The condensing water tube must be installed either directly
backwards from the cooker hood through the wall, if there
is a sewer connection behind the wall (see figure 2 for the
dimensions of the tube location), or to the odour trap of the
sink (Figure 2).
3. The condensing water pipe must be placed at an angle so that
it always points downwards.