INTRODUCTION

IMPORTANT

Apartment-specific 

ventilation units allows 

residents to adjust the 

ventilation efficiency. 

Ventilation is controlled 

based on the need e.g. 

through the cooker 

hood, ventilation 

control panel, or a 

separate control centre. 

In order to ensure that 

the indoor air presents 

no harm to health and 

remains optimal also 

for the structures of the 

building, 

ventilation 

must be kept on 

without disruptions. 

It is recommended 

that ventilation be 

left turned on during 

long holidays also. 

This keeps the 

indoor air fresh and 

prevents humidity 

from condensing in 

the ventilation ducts 

and structures. It also 

reduces the risk of 

moisture damage. 

NOTE

For the MyVallox 

Cloud/Home 

instructions, please go 

to techmanuals.info/

ValloxMV/ENG/help/

webhelp

IMPORTANT

Prolonged overpressure 

can result in damage 

to the structures of the 

building.

VENTILATION UNIT CONTROL 

Ventilation unit control options.

Operation of the Vallox ventilation unit can be controlled by the 

following means:

•  Through the My Vallox Control panel installed in the building.

•  Through the MyVallox Home local area network connection and 

the MyVallox Home/Cloud user interface.

•   Through the MyVallox Cloud service and the MyVallox Home/

Cloud user interface.

•   Through a remote monitoring service or building automation that 

uses voltage signals or Modbus messages.

In addition to the integrated humidity and carbon dioxide sensor, 

ventilation can also be adjusted automatically by using the optional 

carbon dioxide, humidity, or VOC (air quality) sensor. When these 

are used, ventilation remains optimal even when the dwelling 

is unoccupied. Each user can use the week clock to adjust the 

ventilation to fit their individual lifestyle. 

Filter reminder

The unit reminds the user of the need to change the filters through 

the MyVallox Control panel and the MyVallox Home/Cloud user 

interface, as well as by changing the relay status, if a signal light has 

been connected to the relay connectors of the unit.

The filter reminder can be acknowledged:

•  From the MyVallox Control panel

•  From the MyVallox Home/Cloud user interface

•  From the Vallox Delico PTD EC and Vallox Capto PTC EC 

control hoods 

— Damper closed, then open-closed-open-closed. 

Press at a less than 1 second interval.

Ventilation unit setup without a MyVallox 

Control panel

The ventilation unit setup can also be completed without a MyVallox 

Control panel. For instructions, please go to 

https://vallox.techmanuals.info/ValloxMV/ENG/help/webhelp
See instructions provided in the section Connecting the ventilation 

unit to the computer.

Connecting the ventilation unit to the cloud 

service

The ventilation unit can be connected to the MyVallox Cloud service. 

The cloud service allows for controlling ventilation remotely also, 

using e.g. a smartphone or tablet. Also the unit software is updated 

automatically through the cloud service. To connect to the cloud 

service, the ventilation unit must be connected to the Internet via 

LAN and registered with the cloud service. At the same time you 

create a MyVallox Cloud account for yourself. Read more about the 

service at www.myvallox.com.

Содержание 3756

Страница 1: ...Manual Model Vallox 99 MV CF Type 3756 Document D11218 Valid from 01 01 2022 Updated 02 02 2023 Ventilation unit MANUAL...

Страница 2: ...t Klick siphon 9 Space required by the alternative Vallox Silent Klick siphon installation method elbow 9 Measuring and adjusting the air flows of the ventilation unit 9 Dimensions and duct outlets 10...

Страница 3: ...ctrical installations and connections must be carried out only by an electrician and in compliance with local regulations WARRANTY The guarantee and liability exclude damage resulting from Inappropria...

Страница 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor...

Страница 5: ...automatically by using the optional carbon dioxide humidity or VOC air quality sensor When these are used ventilation remains optimal even when the dwelling is unoccupied Each user can use the week cl...

Страница 6: ...supply air fan 8 R model in the figure MAIN PARTS Additional heating resistor 9 Safety switch 10 Internal carbon dioxide and humidity sensor 11 Ceiling bushing for electric wires 12 Control panel 13 C...

Страница 7: ...op edge of the white covering strip of the ceiling mounting plate can be installed against the ceiling Alternatively a concealed mounting method can be used in which case the ceiling can be 30 mm belo...

Страница 8: ...x can be accessed The distance between the service door and the ceiling mounting plate must be around 500 mm Alternatively the cables can be fed to the rear wall between the ceiling mounting plate and...

Страница 9: ...ing tubes These can be inserted in the ducts to allow for easier ventilation adjustment NOTE The Vallox Silent Klick siphon package is delivered with the unit Installation instructions for the siphon...

Страница 10: ...are mirrored 8 Post heating resistor in front of the supply air fan 9 Additional heating resistor 10 Safety switch 11 Internal humidity and carbon dioxide sensor 12 Ceiling bushing for electric wires...

Страница 11: ...ry cell clean The filter replacement interval depends on the ambient particle concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To r...

Страница 12: ...HR cell in place 13 Turn the upper support against the cell Ensure that the upper support is properly nestled against the cell remains upright 14 Install the extract air filter C and the supply air f...

Страница 13: ...d the rubber feedthrough K L through the intermediate floor and to the bottom part of the unit 7 Remove the plastic screws used to fasten the fans I 2 per fan Remove the wing screws J 2 pcs of the pos...

Страница 14: ...three 3 years It is recommended to use compressed air for the cleaning CAUTION When using compressed air the arms of the anemometer must not be allowed to rotate freely This could damage the bearings...

Страница 15: ...45 47 48 48 21 21 21 21 21 22 22 23 23 24 LW dB LWA dB A 75 75 74 75 75 78 78 80 78 80 62 63 71 66 69 71 74 76 81 79 65 65 65 66 67 68 70 71 72 72 44 43 47 45 48 50 53 54 57 57 Sound pressure level co...

Страница 16: ...gital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output T Supply air fan P Extract air fan M Damper motor TK Safety switch AHS Post heating con...

Страница 17: ...2x2x0 5 0 5 2x2x0 5 0 5 2x0 5 2x0 5 CAT Analog input two different functions Potential free contact data 24VDC can be programmed to display information such as errors or to control the valve and pump...

Страница 18: ...External temperature sensor NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Loca...

Страница 19: ...d in the temperature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Manual In summer the duct radiator will turn on when the outdoor tempe...

Страница 20: ...delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 HVAC code 4122110 K Condensing water tube Not included in the delivery IP De...

Страница 21: ...cell bypass damper assembly 4115315 22 Connection box 3526700 5 Coarse and fine filter for supply air 4114075 14 Additional heating resistor 4115412 23 MyVallox Control panel 949033 6 Damper motor 93...

Страница 22: ...CONFORMITY CERTIFICATES...

Страница 23: ...23 Vallox Oy All rights reserved...

Страница 24: ...D11218 23 01 2023FIN 02 02 2023ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Отзывы: