background image

3

© Vallox Oy - All rights reserved

SAFETY

Safe and appropriate handling requires knowledge of the basic safety 

regulations, and of the intended use of the ventilation system. Read 

this manual before operating the ventilation unit. Retain the manual for 

later reference. If you lose the manual, it can be downloaded from our 

website.
This user manual contains all the information necessary for safe 

operation of the system. All persons who operate and maintain 

the ventilation system must follow the instructions provided in this 

manual. Furthermore, all local accident prevention regulations must be 

observed.

Installation

Installation and setup should be carried out only by qualified experts. 

Electrical installations and connections must be carried out only by an 

electrician and in compliance with local regulations. 

GUARANTEE

The guarantee and liability exclude damage resulting from:

•  Inappropriate use of the ventilation system or the control unit

•  Incorrect or inappropriate installation, setup or use

•  Neglect of instructions concerning transportation, installation, use, 

or maintenance

•  Structural or electronic modifications or changes made to the 

software

INTENDED USE

All Vallox ventilation units have been designed to provide appropriate 

and continuous ventilation so as to present no threat to health and to 

maintain structures in good condition.

IMPORTANT

In order to ensure that the indoor air presents no harm to 

health and remains optimal also for the structures of the 

building, ventilation must be kept on without disruptions. It is 

recommended that ventilation be left turned on during long 

holidays also. This keeps the indoor air fresh and prevents 

humidity from condensing in the ventilation ducts and structures. 

It also reduces the risk of moisture damage.

DISPOSAL OF THE VENTILATION UNIT

Do not dispose of electronic devices with household waste. Follow 

local laws and regulations on safe and ecological disposal of the 

product.

NOTE

For further information, 

go to www.vallox.com

  

INTRODUCTION

WARNING

The unit is not intended 

for use by children 

under 8 or by persons 

with reduced sensory, 

physical or mental 

capabilities, or whose 

lack of knowledge 

and experience do not 

ensure safe operation 

of the unit.
Such persons can 

use the unit under 

supervision, or 

by following the 

instructions of someone 

who is responsible for 

their safety.
Children must be 

supervised and not be 

allowed to play with the 

device.

Содержание 3722

Страница 1: ...Manual Model Vallox 096 MV Vallox 110 MV Vallox 145 MV Type 3722 3702 3712 Document D5326 Valid from 3 2 2015 Updated 6 10 2018 Ventilation units MANUAL...

Страница 2: ...e required for installation of the Vallox Silent Klick water seal 10 Space required by the alternative Vallox Silent Klick water seal installation method elbow 10 Dimensions and duct outlets 11 Vallox...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...ted either on the wall or on the floor by using a floor rack optional Vallox 245 MV must always be installed on the floor by using a floor rack NOTE The standard equipment and available accessories va...

Страница 5: ...he control panel installed in the building Through the MyVallox Home local area network connection and the MyVallox Home Cloud user interface Through the MyVallox Cloud cloud service and the MyVallox...

Страница 6: ...ct air filter G4 7 R model in the figure MAIN PARTS Vallox 096 MV Vallox 110 MV and Vallox 145 MV Post heating radiator behind the extract air duct 8 Safety switch 9 Control panel 10 Carbon dioxide se...

Страница 7: ...thread bars so that they withstand the weight of the unit Ensure that the installation plate is horizontally level as this determines the position of the unit Insulate the outdoor air and exhaust air...

Страница 8: ...ing mounting plate must be around 500 mm Alternatively the cables can be fed between the ceiling mounting plate and the ventilation unit to the rear wall When the ventilation unit is lifted against th...

Страница 9: ...fit in the holes at the bottom of the unit Mount the ventilation unit on the wall with a mounting plate as shown in the adjacent figure Make sure that the unit is horizontally level after mounting A...

Страница 10: ...ed the ring seal and the locking part must be moved to the pipe connection part that is mounted on the wall INSTALLATION Dimensioning figure and space required for installation of the Vallox Silent Kl...

Страница 11: ...l 5 Bypass flap R model in the figure In the L model the parts are mirrored 6 Supply air filter G4 7 Extract air filter G4 8 Post heating radiator behind the extract air duct 9 Safety switch Dimension...

Страница 12: ...ter G4 8 Post heating radiator behind the extract air duct 9 Safety switch 10 Additional heating radiator behind the extract air duct Dimensions and duct outlets Dimensions Duct outlets R model Inner...

Страница 13: ...outlets R model Inner diameter of the female collar 200mm 1 Supply air from the unit to the apartment 2 Extract air from the apartment to the unit 3 Exhaust air flowing outdoors from the unit 4 Outdo...

Страница 14: ...coarse filter filters the extract air and keeps the heat recovery cell clean The filter replacement interval depends on the ambient dust concentration It is recommended that the filters be replaced e...

Страница 15: ...gent has been added 8 Rinse the cell clean with a water spray Do not use a high pressure cleaner 9 When all the water has drained from between the layers reassemble the ventilation unit in the reverse...

Страница 16: ...recovery cell 5 Pull out the temperature sensor figure 1 located at the top of the extract air duct G Remove the stopper screw I at the bottom of the duct The extract air duct now comes out by turnin...

Страница 17: ...th a screwdriver for example figure 10 d The fan falls downwards e Pull the fan out of the unit figure 11 f Disconnect the fan wire quick connector figure 12 The fan has now been removed for cleaning...

Страница 18: ...5 Open the four screws figure 1 on the extract air fan cover and remove the cover figure 2 The fan can now be cleaned in place 6 To remove the fan for cleaning a Push the fan gently upward figure 3 b...

Страница 19: ...53 57 57 250 41 51 57 60 62 65 67 68 22 33 39 42 45 49 53 54 500 38 50 54 57 60 63 65 66 28 39 44 47 49 53 55 56 1000 34 48 54 57 59 62 64 65 23 36 42 45 48 51 54 55 2000 24 43 50 55 57 61 64 65 13 24...

Страница 20: ...4 84 90 98 105 Air flow m3 h 104 4 115 2 162 180 183 6 212 4 216 241 2 241 2 270 277 2 302 4 302 4 324 352 8 378 LpA dB A 24 32 32 35 37 40 42 45 Product titles Vallox 110 MV R Vallox 110 MV L Product...

Страница 21: ...alled 10m2 sound absorption ADJUSTMENT POSITION AIR FLOWS supply extract Adjustment position 21 35 41 50 56 65 72 100 Air flow dm3 s l s 36 39 56 62 68 74 81 89 92 98 105 113 116 126 131 142 Air flow...

Страница 22: ...re Modbus A signal RS_B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I...

Страница 23: ...l RS_B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input R...

Страница 24: ...put EXTERNAL ELECTRICAL CONNECTION 3x1 5S 2x2x0 5 0 5 2x0 5 2x0 5 7028350 2014 08 29 JS 2x2x0 5 0 5 2x0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x0 5 2x0 5 CAT Analog input two different functions Poten...

Страница 25: ...ome controls the startup of the pump The pump starts when the supply air setting is below the temperature of the supply air that is blown into the apartment NOTE When selecting the relay C take accoun...

Страница 26: ...mper motor 930620 23 NTC sensor kit 3480500 5 Filter G4 supply 978044 14 Extract air outlet 985026 24 Glass tube fuse 80mA slow 5x20mm 952488 6 Filter stand G4 supply 3464400 15 Internal humidity sens...

Страница 27: ...025 24 Door latch 3355900 6 Filter stand G4 supply 3454000 16 Internal humidity sensor 946148 25 NTC sensor kit 3457900 7 Filter F7 supply 978157 17 Motherboard 949032 26 Glass tube fuse 80mA slow 5x2...

Страница 28: ...ilter stand G4 supply 3466600 16 Internal humidity sensor 946148 25 NTC sensor kit 3482300 7 Filter F7 supply 978158 17 Motherboard 949032 26 Glass tube fuse 80mA slow 5x20mm 952488 8 Lower support fo...

Страница 29: ...CONFORMITY CERTIFICATES...

Страница 30: ......

Страница 31: ......

Страница 32: ...D5326 6 10 2018 PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Aftersales 358 10 7732 270...

Отзывы: