15
© Vallox Oy - All rights reserved
INS
TALLA
TION
The delivery includes the Vallox Silent Klick siphon.
A pipe will be connected to the siphon that leads the
water that is condensed from the extract air to the floor
drain (not directly into the sewer). The pipe must not rise
after the siphon. The ventilation unit must be installed
straight to ensure that condensing water can exit the unit
unobstructed.
Installation of the Vallox Silent Klick
siphon on the bottom pool
Installation of the Vallox Silent
Klick siphon on the wall.
The elbow underneath the
unit takes less space than the
siphon.
47
38
73
53
Elbow
Installation height 38 mm, installation space 47 mm,
outer diameter of the duct 12 mm
Vallox Silent Klick siphon
Installation height 53 mm, installation space 73 mm,
outer diameter of the duct 12 mm
Location of the condensing water outlets,
R and L models
If the Vallox Silent Klick siphon does not fit into the unit
directly, the elbow can be installed at the bottom, and
the siphon can be installed on the wall. This installation
method requires that there is a 47 mm space underneath
the unit. The elbow requires a 38 mm space when
installed.
291
291
147,5
147,5
R model
L model
Installation of the Vallox Silent Klick siphon on the wall
CONDENSING WATER CONNECTIONS
Installation of the Vallox Silent Klick
siphon on the bottom pool
Attic floor penetration plate (optional)
When an attic floor penetration plate is used, the tightness of the vapour barrier has to be ensured.
The attic floor penetration plate can
be fastened on the finished rear wall.
Finished wall
15
15
The minimum distance
from the side walls is 15 mm.