Overview

Valley ClassicPlus Control Panel

   23

Option Switches

The Valley ClassicPlus Control Panel incorporates 
eight expansion slots for optional switches as illus-
trated in Figure 23-1.

4

1

2

3

Figure 23-1 1. Run/Start Switch - Installed on all ClassicPlus 

Panels

2. Auto Reverse/Auto Stop - Installed with the 

optional drive unit mounted auto reverse/auto 
stop hardware

3. Auxiliary Switch - Installed with the optional 

auxiliary control

4. Expansion Slots

Engine Run/Start Switch

A standard engine RUN/START 
switch is installed for easy wiring of an 
engine shutdown circuit. See Figure 
23-2.
If the switch is in the RUN position, the 
engine would shut down if the pivot 
system stops for some reason. The 
switch MUST be in the START posi-
tion to start the engine.

Auxiliary On/Off Switch

This optional switch is available for 
such uses as injector pump opera-
tion, manual end gun control or other 
options the operator may decide to 
install. See Figure 23-3.

Figure 23-3

Figure 23-2

Auto Reverse/Auto Stop Switch

This switch will only be installed if 
the optional drive unit mounted auto 
reverse/auto stop is ordered as illus-
trated in Figure 23-4. 
In the Auto Reverse position, the 
system will run continuously, au-
tomatically reversing when either 
actuator arm is tripped. 
In the Auto Stop position, the sys-
tem will Stop when the actuator arm 
is tripped.
The Drive Unit Mounted Auto Reverse/Auto Stop as-
sembly is used for both drive unit mounted end of 
field auto stop and drive unit mounted end of field 
auto reverse/auto stop (combined options). See Fig-
ure 23-5.

1

3

2

Figure 23-5 1. Actuator Arm

2. Structure to Trip Actuator Arm
3. Physical Barricade (Required)

The auto stop option will stop the system when the 

actuator arm contacts the barricade. 
If the auto reverse/auto stop option is installed, the 
operator may choose to either stop the system when 
it reaches the barricade or have the system automati-
cally reverse its direction of travel and continue to run. 
This can be selected with the Auto Reverse/Auto Stop 
switch as illustrated in Figure 23-4.

NOTE

• Care must be taken when this option is used. 
• The operator MUST ensure the actuator arm 

contacts the tripping structure. Under certain 
conditions, soil may build up in the wheel 
track resulting in a ramp effect allowing the 
actuator arm to go over the tripping structure 
without tripping the actuator arm.

Figure 23-4

Содержание ClassicPlus

Страница 1: ...2019 Valmont Industries Inc Valley NE 68064 USA All rights reserved www valleyirrigation com Valley ClassicPlus Control Panel Owner s Manual 0998940_C...

Страница 2: ...Valley ClassicPlus Control Panel 2...

Страница 3: ...ice 11 Operate Safely 12 Safety Decals 16 Overview 19 Controls and Components 19 Main Disconnect Switch 20 3 Second Auto Restart 20 Start Stop Switch 20 Forward Reverse Switch 20 Wet Dry Switch 21 SIS...

Страница 4: ...Table of Contents Valley ClassicPlus Control Panel 4...

Страница 5: ...1 Irrigation Machines Statement regarding Pressure Equipment Directive 97 23 EC The Crop Irrigation System is excluded from the scope of the Pressure Equipment Directive by the language of Article 1 S...

Страница 6: ...connected from the irriga tion machine structure to a ground rod and another cable from the irrigation machine structure to the ground terminal on generator in order for the differential ground fault...

Страница 7: ...he equipment or damage the equipment Safety Messages Safety messages in this manual are preceded by the hazard symbol and one of three words DANGER WARN ING or CAUTION These messages alert you to pote...

Страница 8: ...russ rods pipes angles and ladders in areas with energized power lines exposed conductors or circuit parts work practices such as the use of insulation guarding and material handling techniques must b...

Страница 9: ...al airport authority for guidance and specific recommendations In the United States guidelines for marking structures near airports are published by the Federal Aviation Administration in Advisory Cir...

Страница 10: ...ther environmental conditions will increase the possibility of electrocution and require additional consideration Transmitter towers can induce the equipment or materials being handled with an electri...

Страница 11: ...itch close valve etc 4 De activate the energy isolating device s so that the machine or equipment is isolated from the energy source s 5 Lock out the energy isolating device s with assigned individual...

Страница 12: ...and what to do in case of emergencies EMERGENCY STOPPING The machine can be stopped at any time at any tower by turning the disconnect switch located underneath the tower box to the OFF position Refer...

Страница 13: ...re 13 2 CAUTION QUALIFIED SERVICE PERSONNEL If you do not understand electricity or other parts of the machine have qualified service personnel per form any hazardous repairs or maintenance CAUTION GU...

Страница 14: ...ut warning DO NOT TOUCH ROTATING DRIVE SHAFT OR SHIELD CLOTHING OR LIMBS MAY BECOME ENTANGLED RESULTING IN SEVERE INJURY DO NOT SERVICE THE MACHINE UNTIL THE MAIN DISCONNECT IS LOCKED IN THE OFF POSIT...

Страница 15: ...mediately discontinue use and adjust the shutoff setting or call your Valley dealer to repair the end gun shut off mechanism CAUTION AUTO REVERSE OPERATION SAFETY If the machine reverses direction at...

Страница 16: ...Danger Warning and Caution decals appear in various locations on a Valley irrigation machine You MUST familiarize yourself and other operator s with these safety decals For replacement of any decal co...

Страница 17: ...27 Auto Reverse Safety Switch 181 28 Switch Only 03E 29 Switch Mount 178 30 10 Hex Nut 013 31 10 x 2 1 2 R H Machine Screw 016 32 Retro t Split EGSO Ring Half 2 req d 178 3 1 2 x 1 1 2 Cap Screw 01610...

Страница 18: ...become entangled resulting in severe injury Do not service until machine is locked in the off position Always replace drive shaft shield after servicing Drive Shaft Starts Without Warning DANGER Do no...

Страница 19: ...RIOR CONTROL PANEL DOOR SERVICE WORK DONE ON THE CONTROL PANEL IS TO BE PERFORMED BY A QUALIFIED SERVICE PERSON ONLY ClassicPlus AUTO REVERSE AUTO STOP LINEAR PIVOT 1 2 3 4 5 6 7 8 9 10 11 12 13 Figur...

Страница 20: ...unit mounted auto reverse auto stop is installed The standard switch those panels ordered without the optional drive unit mounted auto reverse auto stop will either be in the For ward or Reverse posi...

Страница 21: ...ich completes the safety circuit and allows the system to run Therefore if the Wet Dry switch was in the WET po sition and the pressure dropped below 15 psi 103 kPa the system would shut down thus pro...

Страница 22: ...rcent timer settings Hour Meter Records the number of hours the system has operated includ ing both hours with and without water or wet and dry time See Figure 22 2 Volt Meter The volt meter displays...

Страница 23: ...rse auto stop is ordered as illus trated in Figure 23 4 In the Auto Reverse position the system will run continuously au tomatically reversing when either actuator arm is tripped In the Auto Stop posi...

Страница 24: ...Overview Valley ClassicPlus Control Panel 24...

Страница 25: ...e driven genera tor adjust the RPM of the generator until the voltmeter reads 480 505 volts DO NOT EXCEED 505 VOLTS 8 Place the WET DRY switch in the WET position 9 Select the direction of travel by p...

Страница 26: ...wise and Reverse is counter clockwise 6 Press the START STOP switch to the START lo cation for 1 2 seconds and release The system should now start 7 Place the Engine RUN START switch in the RUN positi...

Страница 27: ...See Figure 27 2 3 Turn the pumping unit OFF if not automatic 4 If an engine generator set is utilized place the Engine Run Start switch to the Start position for the next start up sequence WARNING DO...

Страница 28: ...with the control panel NOTE If the system fails to start call your autho rized Valley dealer and relay your observa tions of the PANEL and TOWERS lights during start up procedure End Tower Light The E...

Страница 29: ...ION MUST BE TAKEN BY THE OPERATOR WHEN THIS BUTTON IS DEPRESSED AS IT WILL BY PASS OR DISABLE ALL OF THE SYSTEM S SAFETY CIRCUITS NEVER DEPRESS THIS BUTTON FOR MORE THAN 3 TO 5 SECONDS IF THE SYSTEM I...

Страница 30: ...started Machine Running When a change is made to the Eagle solid state percent timer setting dur ing operation the change is not immediately recognized by the percent timer First the percent timer com...

Страница 31: ...mer the End tower light should be ON for 12 seconds and OFF for 48 seconds If the End Tower indicator light is ON for more than 13 seconds or less than 11 seconds the percent timer is not operating pr...

Страница 32: ...NT TIMER SETTING HOURS PER REVOLUTION 0 15 3 8 100 21 0 20 5 1 77 28 0 30 7 6 51 41 0 40 10 2 39 55 0 50 12 7 31 69 0 60 15 2 26 83 0 70 17 8 96 96 0 80 20 3 19 110 0 90 22 9 17 124 1 00 25 4 15 138 1...

Страница 33: ...Hours Per Revolution at 100 0 105 DLRDU in Meters Speed in ft min Speed in M min Example Example DLRDU 1260 ft DLRDU 384 M Speed in Feet Per Minute 6 77 ft min Speed in Meters Per Minute 2 06 M min H...

Страница 34: ...ill apply Inches Per Day GPM 735 3 Millimeters Per Day LPS 735 3 SL 2 SL 2 735 3 735 3 2 2 _______ _______ 4 Determine Hours Per Revolution at 100 Percent Timer Setting Hours Per Revolution at 100 0 1...

Страница 35: ...10 ______ In mm Rev 5 _____ 0 05 ______ In mm Rev Operation Percent Timer Setting Calculation Worksheet Continued 6 Determine Inches millimeters Per Revolution and Hours Per Revolution for any percent...

Страница 36: ...an the ply rating of the old tire The 11 2 24 four ply Titan tires are specially constructed with a 6 ply bead and must be replaced with the same Valmont part num ber 0991257 or with a 6 ply tire WARN...

Отзывы: