WHAT KIND OF WOOD

 

There is an old idea that you should use some green wood to insure long burn times.   THIS IS WRONG!  
Always remember, the dryer the wood the better.  It takes a great deal of energy to evaporate the moisture 
contained in green wood and that energy will not be heating your house.  Green or wet wood also  increases 
creosote formation. 

 

In most cases the harder the wood the more heat it produces,. In all cases the dryer the wood the more heat it 
produces.  We recommend at least 12 months drying time for split piled wood, protected from rain. 

 

Your wood burning furnace is not designed to burn coal and doing so is unsafe. Burning coal voids the 
warranty.

 

Never burn salt water drift wood. It is very corrosive and will damage the firebox.  Burning salty 

wood also voids the warranty. 

 

This controlled combustion firebox has been designed for high efficiency and long burn times.   The proper 
time to add more wood is when the last charge has been reduced to a glowing charcoal bed stage.  There will 
be very little smoke at this stage in the burn cycle. 

 

WARNING: BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE 
ACCUMULATION.  WHEN CREOSOTE IS IGNITED IT CAN CAUSE A CHIMNEY FIRE WHICH 
MAY RESULT IN A SERIOUS HOUSE FIRE 

 

OPERATIONS

 

Draft is created by the heated air rising in the chimney system.  This draft will pull fresh combustion air 

into the firebox. Recommended draft is .03 in. w.c.  Too little draft results in a sluggish fire and smoke 
backing up into the house when the furnace door is opened.  Too much draft (over .06 in. w.c.) is unsafe 
and wastes fuel. (Use a Barometric damper when necessary) 

The damper opening has been set at the factory and should not be adjusted. 

Ashes should be cleaned out when they reach a depth of 4" in the firebox.  Leave approximately 1" of ashes 

in the bottom of the firebox.  Dispose of ashes in an airtight, metal container and store it outside away 
from combustibles. 

Adjust the bleed air screw on the damper door to just maintain combustion air during times when the 

damper door is closed .    

OPEN THE FIRING DOOR ONLY TO RELOAD FUEL.   

Your appliance must be vented by a chimney system suitable for solid fuel fired appliances and should be 

checked periodically to insure its safe condition.    

During a power failure, use extreme caution to not over fire.  Leave the damper closed.  Remove the blower 

cabinet door and air filter. Open all registers to allow maximum air flow in the duct system.  Although 
there is considerable heat available even during a power failure,  this furnace is not approved for gravity 
operations. Without the blower running, high temperature in the system builds up quickly and over firing 
will result in permanent damage to the firebox. Maintain a small fire only.  Over firing voids all product 
warranties. 

If your furnace is operating as an add-on combination unit remember both units will not fully fire at the 

same time.  If wood is to be your main source, set the wood thermostat at your desired room temperature 
and set the backup thermostat approximately 5 degrees lower.

 

 

 

Содержание MP80

Страница 1: ...50 493 7444 www blazeking com Email sales blazeking com READ THOROUGHLY AND COMPLY WITH ALL LOCAL CODES AND REGULATIONS MP80 SOLID FUEL FURNACE FOR USE AS AN ADD ON TO OIL GAS OR ELECTRIC FURNACE OR A...

Страница 2: ...MP80 PUB Version 1 07 2...

Страница 3: ...UDED 14 OPTIONAL EQUIPTMENT 14 INSTALLATION OPTIONS 14 TYPICAL INSTALLATION DIAGRAMS 15 CLEARANCES 16 ALTERNATE FURNACE LOCATIONS 16 PRESSURE LOSS 17 COMBUSTION AIR 17 INTERCONNECT DUCT RETAINERS 17 F...

Страница 4: ...ept as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitat...

Страница 5: ...see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim sh...

Страница 6: ...wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 11 The Limite...

Страница 7: ...air work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 26 At no time will Blaze King be liable for any consequential damages which exceed the purch...

Страница 8: ...plenum opening 30 5 8 L x 18 W Fire door opening 12 x 13 Firebox length 26 Width 14 Height 19 Capacity 4 cu ft Fuel length 24 Firebox design features 1 distributed draft system with preheated primary...

Страница 9: ...Combustible material including firewood must be stored well away from the furnace outside of the distances specified for clearance to combustibles Never operate the furnace unless you are sure the smo...

Страница 10: ...this booklet thoroughly and save it for future reference Carefully follow instructions for installation OPERATING INSTRUCTIONS LIGHTING THE FIRE NEVER START A FIRE UNLESS THE FURNACE IS CORRECTLY INST...

Страница 11: ...ttle draft results in a sluggish fire and smoke backing up into the house when the furnace door is opened Too much draft over 06 in w c is unsafe and wastes fuel Use a Barometric damper when necessary...

Страница 12: ...y cleaning to remove creosote buildup Remember the hotter the fire the less creosote A large smoldering fire causes more creosote than a small high heat fire We recommend that each day preferably in t...

Страница 13: ...E IS BE ING OVERFIRED OPERATE THE ALTERNATE ELECTRIC GAS OR OIL FURNACE PERIODICALLY TO EN SURE THAT IT WILL OPERATE SATISFACTORILY WHEN NEEDED INSPECT VENT PIPES VENT PIPE JOINTS AND VENT PIPE SEALS...

Страница 14: ...150 or equivalent White Rodgers 5D51 78 set at 220 or equivalent White Rodgers 5D51 78 set at 250 or equivalent Thermostat White Rodgers 1E78 or equivalent Poker Ash shovel Instruction book Insulation...

Страница 15: ...OOD COUNTERFLOW INSTALLATION REQUIRES NOTE IN THIS CONFIGURATION SPECIAL CLEARANCES APPLY SEE CF6KIT INSTRUCTIONS DO NOT INSTALL IN THIS CONFIGURATION WITHOUT USING THE CF6KIT CF6 KIT OPTION ALTERNATE...

Страница 16: ...on and maintenance of wood heating systems across Canada For your safety and satisfaction your system must be properly installed MINIMUM CLEARANCES TO COMBUSTIBLES See label copy addendum If the furna...

Страница 17: ...e drop Static pressure at furnace minus static pressure at duct exit Record the pressure drop of the original system Addition of the add on furnace will add air flow resistance in the system After ins...

Страница 18: ...chimney connector must be attached to either an approved masonry chimney or one of the listed factory built chimneys suitable for use with solid wood fuel All joints must be tight and fastened with sh...

Страница 19: ...not necessarily assure proper flue draft Use a minimum total system height of 12 feet measured from the stove flue collar to the top of the chimney not including the chimney cap THERMOSTATS Stand alo...

Страница 20: ...must not compress leads tightly against the surface DOOR AND LATCH INSTALLATION Install the firebox door on the frame hinges Install the door latch catch on to the frame mounting bracket as shown bel...

Страница 21: ...l also THE OPERATION OF THE GAS FURNACE MUST BE VERIFIED FOR ACCEPTABLE OPERATION BEFORE AND AFTER INSTALLATION OF THE ADD ON BY A GAS FITTER WHO IS RECOGNIZED BY THE REGULATORY AUTHORITY DO NOT CONNE...

Страница 22: ...S INDEPENDENT WOOD FURNACE When installed with a blower cabinet mounted on either side the MP80 becomes an INDE PENDENT wood only furnace The blower must have a minimum 900 cfm capacity In this config...

Страница 23: ...ECTIONS WHEN USING ELECTRICAL FURNACE WITH W1 R C G CONNECTIONS You must connect the alternate furnace thermostat through the interlock limit switch to provide interlock lockout of the alternate furna...

Страница 24: ...hen installing in a stand alone configura tion with a VB1000 blower Only 2 out of the three limit switches are used The middle limit is the Operating Limit and the right limit switch is the Safety Lim...

Страница 25: ...10V Motor Adjustable from 900cfm to 1200 cfm 20Ga Steel Cabinet Construction High Quality Baked Enamel Finish Color matched to Valley Comfort Wood Furnaces Complete with 24 X 20 Air Filter Please chec...

Страница 26: ...MP80 PUB Version 1 07 26...

Отзывы: