spotWave Instructions Manual 

Instructions Manual 

 

Revision 2022-07 

Содержание spotWave 201

Страница 1: ...spotWave Instructions Manual Instructions Manual Revision 2022 07...

Страница 2: ...Misuse 14 12 Hardware Types 15 12 1 Mechanical Properties 16 13 Operating Elements of a spotWave Device 17 13 1 USB Mini B Connector 17 13 2 LED 17 13 3 Sensor Connector in 18 13 4 CCT Connector out...

Страница 3: ...Provided in Other Resources The spotWave Operation Manual describes the usage of the spotWave acoustic emission measurement device with a focus on the acquisition and analysis software The technical...

Страница 4: ...ufacturer of Acoustic Emission measurement systems and accessories for acoustic emission testing Vallen Systeme GmbH Buergermeister Seidl Str 8 82515 Wolfratshausen Germany telephone 0049 8171 38391 0...

Страница 5: ...may be used or copied only in accordance with the terms of such license AMSY 6 ASIP 2 spotWave conditionWave linWave WaveLine SmartLine VisualAE VisualClass and VisualTR are trademarks of Vallen Syste...

Страница 6: ...anual NOTICE A NOTICE notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or l...

Страница 7: ...2022 07 file spotwave_instructions_manual docx 7 of 50 5 Safety Symbols No safety symbols are used on the device...

Страница 8: ...this product have been impaired either through physical damage excessive moisture or any other reason remove power and do not use the product until safe operation can be verified by service trained p...

Страница 9: ...e the spotWave device to a moist and wet environment in mated condition meaning with AE sensors CCT device connected and USB connector securely fixed Do not expose the device to dirt and humidity or s...

Страница 10: ...Firmware Updates Vallen Systeme GmbH releases software updates including new firmware for its measurement devices to i add new features ii include product enhancements and iii fix software issues The...

Страница 11: ...llected over the LAN interface by an acquisition software that is running on a host device conditionWave conditionWave is a trademark of Vallen Systeme and the type designation of a dual channel AE me...

Страница 12: ...E data autonomously After finishing the logging mode an end device is used to collect the accumulated AE feature data via the USB connection Figure 2 spotWave measurement system logging mode as block...

Страница 13: ...light or iii measuring the speed of sound Acquisition software compatible to Android 8 or later and Windows 10 is part of the spotWave device A license for using the VisualAE analysis program is also...

Страница 14: ...specially do not use it with e g temperature sensors strain gauges displacement sensors or AE sensors with RMS and or stretched APK output The spotWave device is rated IP67 in mated condition The spot...

Страница 15: ...t The spotWave device code consists of type _ sampling rate channel number _ input range dBAE type device type designation spotWave sampling rate max sampling rate in MHz channel number double digit c...

Страница 16: ...x 14 mm x 58 mm W x H x D Weight 107 g Ingress Protection IP67 Connector 2x SMA female 1x USB mini B female LED 1x RGB LED for indicating operational conditions No ingress of dust complete protection...

Страница 17: ...Connect a USB power bank instead of an end device to power the spotWave device and for running it in Logging Mode see next section 13 2 LED The LED indicates the status of the device Property Descrip...

Страница 18: ...dance 16 k 12 pF 50 mV 100 mV input range 500 k 940 pF 5000 mV input range Input range 94 dBAE 50 mV 100 dBAE 100 mV 134 dBAE 5000 mV The input range is defined by hardware and marked on the device 13...

Страница 19: ...card board box It shall be used for storage and transportation since it offers protection against shock Make sure that the environmental conditions are within specified limits during storage transport...

Страница 20: ...To power it connect the device to a PC or mobile device or a battery pack with USB interface The spotWave device s LED is switched to blue if it is powered 15 1 1 Power Requirements Description Specif...

Страница 21: ...a PC or laptop that is used as end device for the spotWave device The end device runs the data acquisition and the measurement data is stored to its disk drive PC Requirements OS Windows 10 CPU minimu...

Страница 22: ...16 2 Connecting a Coupling Check Transducer Only connect a device from Vallen Systeme that is labelled and specified as Coupling Check Transducer CCT For connecting the CC transducer to the spotWave...

Страница 23: ...spotWave processor s feature extraction unit Intensity analysis of recorded data can be done based on the peak amplitude energy and the number of threshold crossings of a hit Activity analysis can be...

Страница 24: ...signal TRAI Transient recorder index database key of transients in the transient data file used as common key in the primary data file 16 5 Command Set The spotWave is a USB CDC Communications Device...

Страница 25: ...50 16 5 1 States and transitions The executable commands are dependent on the device state Following diagram shows the possible states and transitions IDLE RECORDING LOGGING logging 0 logging 1 loggi...

Страница 26: ...tetime 28 set_filter 28 start_acq 29 stop_acq 29 get_ae_data 29 get_tr_data 31 get_tr_snapshot 31 get_data_log 32 clear_data_log 32 get_info 32 get_status 33 get_setup 33 set_acq thr Set threshold for...

Страница 27: ...000 0 disabled Valid state IDLE set_acq tr_enabled Enable disable transient data acquisition Command set_acq tr_enabled 0 1 Valid state IDLE set_acq tr_decimation Set decimation factor for transient...

Страница 28: ...r time of flight measurements When command get_tr_snapshot is issued the CCT is activated and the transient recorder starts simultaneously The time difference from start sample to the sample of first...

Страница 29: ...17 D 10000000 C 0 E 38788614 TRAI 0 flags 0 n H temp 27 T 43686000 A 31004 R 496 D 703 C 4 E 74860056830 TRAI 1 flags 0 n H temp 27 T 43686983 A 15545 R 279 D 624 C 5 E 42194101126 TRAI 2 flags 0 n n...

Страница 30: ...The conversion factor to engineerign units of V s is 2 2 2 1 Vallen Systeme software uses arbitrary energy units eu A conversion to energy units is done the following way with the scaling factor 106 f...

Страница 31: ...ains the information of the transient recorder index TRAI arrival time T and number of samples NS The header line is followed by the ADC samples as binary data int16 2 x NS bytes The conversion to V i...

Страница 32: ...ta_log Valid state LOGGING IDLE Response The response syntax is the same as for get_ae_data An additional record with the type flag R and the acquisition start timestamp is returned first All followin...

Страница 33: ...ation Command get_status Valid state ALL Response temp 26 C n recording 0 n logging 0 n log_data_usage 1636 sets 0 12 n date 2020 12 17 19 23 40 140 n get_setup Read setup information Command get_setu...

Страница 34: ...oth responses end with an empty line if there are no further records to read and parse The get_data command just returned the ASCII or binary ADC values without any header or final line A headerline w...

Страница 35: ...flags 0 n S temp 27 T 20024576 A 22 R 588985 D 2000000 C 0 E 38857408 TRAI 0 flags 0 n get_tr_data n retrieve transient data of hits 0 n no hit so far produce a hit get_ae_data n 2 n S temp 27 T 2010...

Страница 36: ...OM4 If unsure just unplug and plug the spotWave s USB cable while watching the Device Manager You will see the right COM port disappear and appear again If the Vallen AE Suite Software is installed th...

Страница 37: ...2022 07 file spotwave_instructions_manual docx 37 of 50 Now you are ready to communicate with the device Test with a simple get_info command...

Страница 38: ...s vallen de AE sensors with microdot connector are connected with a type CBL 1 1M2 V63 cable to the spotWave device AE sensors with an SMA connector are connected with a type CBL 1 1M2 V70 cable to th...

Страница 39: ...rolled by the spotWave device and can be used to stimulate artificial acoustic emission Mounted to the surface of an object the CCT can be used to excite elastic waves in the object in a controlled ma...

Страница 40: ...alfunction or damage 19 1 System Verification The device s function can be checked against specifications A so called verification of function according to specification is recommended to be done once...

Страница 41: ...structions_manual docx 41 of 50 20 Compliances Statement The spotWave device complies with following directive Directive 2014 30 EU EMC A spotWave AE measurement system complies with following standar...

Страница 42: ...edure Owners of old instruments request our agreement with the return of old instruments The goods to be returned must be described unambiguously and identified by serial number and or the identificat...

Страница 43: ...European Union Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment RoHS Directive 2011 65 EU The RoHS directive prohibits the sale of electronic equipment con...

Страница 44: ...es Signal processing Specification Analogue pass band filter high pass 20 kHz 2 nd order low pass 500 kHz 6 th order ADC 2 MHz at 16 bit Application specific filters IIR pass band filter Butterworth c...

Страница 45: ...00 dBAE 134 dBAE Ums resolution approx 1 75 V 3 5 V 175 V Rise time resolution 500 ns Duration resolution 500 ns Hit flags Flag Description T hit time out Duration 100 ms A artificially started hit af...

Страница 46: ...ftware selectable decimation factor Duration adapted recording mode number of samples that are recorded per trigger depends on duration of the burst signal pretrigger samples and post duration samples...

Страница 47: ...ia telephone 61 3 9574 6144 mobile 61 418 993 755 mail austin attar com au Latin America except French Guayana Xcel Inspection Solutions Ltd Flat 7 Elton Lodge Florence Road W5 3TX Ealing London Unite...

Страница 48: ...ce Tower 1st Floor Jasola District Center NEW DELHI 110025 INDIA telephone 011 41494034 fax 011 41494004 5 mail amitdhillon bluestarindia com Italy ETS Sistemi Industriali SRL Via S Francesco 323 2086...

Страница 49: ...ia Total Control S R L Calea Calarasi 38 B 030624 BUCRESTI 3 ROMANIA telephone 40 21 2123151 mail office tcontrol ro Russia Panatest LLC NDT Department V 302 17 Krasnokazarmennaya str Moscow 111250 Ru...

Страница 50: ...D ARAB EMIRATES telephone 971 4 432 3551 fax 971 4 4342415 mail feras_ayoub islte ae United Kingdom Omnia Integrity Ltd Boundary House Boston Road London W7 2QE United Kingdom telephone 0044 208 089 8...

Отзывы: