3  Configuration menus and parameters 

3.1.1

 

Setup Menu - item entry 

When in each of the menu items you will be asked to respond to a question. For 
example: “Enter 33.3 rpm frequency, Hz: (45 – 65): 50.0”. The question will be 
followed by the units, the range of acceptable values in between the brackets (45 - 
65), and finally the current value: 50.0. Either provide a new value within the range 
specified or press the Return key (CR) to accept the current value. The section 
questions will repeat until the Q key is pressed. The Q key can pre pressed at any 
time, not just at the end of a section to exit the current setup menu. 
 

3.1.2

 

System Parameters 

Configuration items in this menu relate to general behaviour of the overall controller. 
If you live in the UK and are using a 110v synchronous motor, then the default values 
should work fine. Worldwide users may need to set the 33.3 & 45 rpm frequencies: 
 

Parameter / Description 

Units 

Range 

Default 
value 

Enter 33.3 rpm frequency, Hz: 
The frequency that needs to be supplied to the 
motor to achieve 33.3 rpm rotation 

Hz 

30-65 

50 

Enter 45 rpm frequency, Hz: 
The frequency that needs to be supplied to the 
motor to achieve 33.3 rpm rotation 

Hz 

65-90 

67.5 

Soft start frequency delta, Hz: 
The difference from the 33.3 rpm starting 
frequency when first powered on. 

Hz 

0-30 

10 

How many phases on motor: 
The number of windings on the motor you are 
controlling. Most synchronous motors are 2 
phase. Three and four phase motors require an 
additional expansion board that contains 
additional DDS generators and motor amplifiers. 
 

1-4 

Motor full speed voltage, %: 
When the motor is running at full speed (WOW 
<=0.02%) the voltage drive can be reduced in 
order to reduce motor vibration. This parameter 
will reduce the drive from 100% to the specified 
value. Keep at 100% if feature is not used. You 
must have a platter sensor for this function to 
work. 

50-100 

100 

Power standby sleep time, min: 
If the motor drive is idle (not spinning) for longer 
than the specified period, the board switches to 
low power/sleep mode. It is woken by pressing 

Min 

1-360 

60 

Содержание Zeus

Страница 1: ...Zeus Turntable Motor Speed Controller Tachometer...

Страница 2: ...tive Speed Control PID 12 2 5 1 Turntable PID values 12 2 5 2 Final installation note 13 3 Configuration menus and parameters 14 3 1 1 Setup Menu item entry 14 3 1 2 System Parameters 14 3 1 3 Motor P...

Страница 3: ...atter rotation speed and using the PID algorithm adjustment of the AC signals fed to the motor is possible The feedback loop created by the sensor and PID result in accurate speed control and low WOW...

Страница 4: ...itch is a standby switch The board may be configured to go into a low power sleep state after a period of inactivity The procedure for installation is in two parts Basic installation and adaptive PID...

Страница 5: ...lexible cable attach to the black connector marked LINN PSW1 with the copper contacts uppermost If using the supplied switch remove the existing square LINN switch and replace with the square switch P...

Страница 6: ...uld get you through the basic testing for the board To configure the board for basic testing use the PIDTuning application or a serial console application set to 9600 N 8 1 Interaction with the contro...

Страница 7: ...question For example Enter 33 3 rpm frequency Hz 45 65 50 0 The question will be followed by the units the range of acceptable values in between the brackets 45 65 and finally the current value 50 0 E...

Страница 8: ...he IR sensor lightly Connect the other end of the 4 way FFC cable to connector P3 on the underside of the motor controller PCB silver contacts towards the PCB Position the IR sensor diodes to the outs...

Страница 9: ...gered Hand rotate the platter and adjust the position the speed box so that each time the marker passes the trigger message is displayed Also brief flash from the IR sensor registration indicator LED...

Страница 10: ...ral bearing hole or other available access point However ensure there are no sharp edges to damage the insulation of the FFC cable Often the bearing bolt heads have sharp edges so endure the FFC cable...

Страница 11: ......

Страница 12: ...variables and step through the questions setting values for Kp Ki and Kd Quit out to main menu and write the changes to EEPROM using option 6 You may find the turntable takes a little longer to reach...

Страница 13: ...slight adjustment of phase angles you can significantly reduce motor vibration and hence audible noise Some of the parameters require a re boot of the controller to take effect remember to write to th...

Страница 14: ...value Enter 33 3 rpm frequency Hz The frequency that needs to be supplied to the motor to achieve 33 3 rpm rotation Hz 30 65 50 Enter 45 rpm frequency Hz The frequency that needs to be supplied to th...

Страница 15: ...e label Y N N Automatically start platter on application of power The board can automatically start the platter on the application of power rather than having to press a start switch Y N N Crystal tri...

Страница 16: ...us motors 85v rms is a good starting point Slight adjustment of phase voltages can reduce motor vibration Start with the defaults and adjust on test If you can hold the motor in your hand this is the...

Страница 17: ...333 60 0 55555 0 1 0 66666 Debug PID to Serial Monitor Displays setpoint output feedback values to the serial console When adjusting the PID values using the PIDTuning app this parameter will be set t...

Страница 18: ...on of restoring force proportional to the rate of change derivative of position error This force is much like viscous damping in a damped spring and mass mechanical system a shock absorber for example...

Страница 19: ...in Use Step Response to determine the relative stability of the system A system is considered stable if the actual value is finite when the commanded value is finite In other words a system is stable...

Страница 20: ...e maximum overshoot directly indicates the relative stability of the system Commanded Position the desired position or rotation speed In this case the commanded value is 1 000 For the Zeus motor contr...

Страница 21: ...ed system is characterized by a large overshoot a long settling time and short peak and rise times A critically damped system response provides a balanced medium between over and under damping This ty...

Страница 22: ...ance graph for observing small response changes Perform the following steps to tune your PID control system You are aiming for a critically damped response 1 Set all three PID parameters Kp Kd and Ki...

Страница 23: ...t 1 50 of Kd this will mean that the response will no longer oscillate but will quickly dampen to a steady state value Try to eliminate any peaks You may need to enable the Auto Zoom feature to see th...

Страница 24: ...alues by small amounts to achieve the fastest response with minimal overshoot and correction Monitoring fluctuations in the WOW value on the serial monitor is a good indicator Go back to your recorded...

Страница 25: ...reases the slope of the initial rise to the commanded position As you increase Kp you approach the commanded position faster and thus overshoot by a greater amount Kd reduces the oscillations over a p...

Страница 26: ...master file CH34x_Install_V1 3 zip If you do not have a serial monitor program use the one build into the Arduino IDE Follow the instructions at this link https www arduino cc en Guide MacOSX toc1 Onc...

Страница 27: ......

Страница 28: ...al switch on 20mA steady state at 230V Replacement Fuse T500mA 250v Dimensions 20 x 165 x 100mm HxWxD Motor Output drive voltage 12v to 110v AC Motor Output drive current 20mA Frequency resolution 0 0...

Отзывы: