810
Thermo H plus
8 Repairs
8.3.4 Combustion air fan removal/installation
Removal
1. Remove burner (see
).
2. Withdraw combustion chamber (1,
) from out
the heat exchanger (2).
Installation
ATTENTION:
When replacing the combustion chamber, ensure that
the new combustion chamber corresponds to the
heating capacity class of your heater.
1. Slide combustion chamber (1,
) fully into the
heat exchanger (2) against stop. Pay attention to
a) the welding seam position, and
b) the position of cut-outs in the combustion chamber
head.
NOTE:
– The combustion chamber should be inserted into the
heat exchanger in such a way that its welding seam is
positioned between 2 and 10 o clock (not upwards!)
).
A position change during maintenance is permissible
and affects the expected service life of the combustion
chamber positively.
– Position the cut-outs in the combustion chamber head
as shown in
.
Dripping from nozzle fuel is so collected in a reservoir
between disc and burner head and will be burned at
the next burner operation instead to soil the heater.
2. Install burner (see
).
Fig. 811 Combustion chamber / heat exchanger removal/installation
1 Combustion chamber
2 Heat exchanger
3 Exhaust outlet
4 Vibration damper
5 Coolant inlet
6 Coolant outlet
7 Coolant hose (2x)
8 Hose clamp (2x)
9 Stud bolts
Position of the welding seam
Position of the cut-outs in the combustion
chamber head when installed
when installed
Cut-outs
o.k.
Not permitted!
4
4
6
3
5
2
7
8
6 ±0,6 Nm
6 ±0,6 Nm
7
8
9
2,5 ±0,25 Nm
1
Содержание Thermo H 160