5. Repairs
5.1 Simple faults
Fault
Possible cause
Remedy
The fryer is no longer heating.
No lamp lights up
The red lamp lights up
∗
No power
∗
Safety thermostat has
switched off
◊
Check fuses, plugs and socket
◊
Press reset button (see 5.3)
The fryer is not heating
sufficiently
∗
One phase is missing on
the power supply cable
◊
Check fuses
The fryer is not heating
sufficiently
∗
The switch has remained
on "Melt"
◊
Turn button to "Fry"
Oil cock is sticking
∗
Sticking due to old oil
residues
◊
Actuate frequently with hot oil.
i.e. filter oil daily
The special mains cable must only be replaced by the manufacturer or his customer service
representative.
5.2 Complex faults
Fault
Possible cause
Remedy
The signal lamps come on, but
the fryer is no longer heating
∗
Heating element defective
◊
Call the service centre *
The
fryer
is
not
heating
sufficiently
∗
Interruption of a phase
∗
Heating element defective
◊
Call the service centre *
The fuses blow when fryer is
switched on
∗
Short-circuiting
◊
Call the service centre *
The fault current safety switch
(FI) in the fuse box switches off
∗
Moisture or poor insulation
in the electrical circuit
◊
Call the service centre *
The colourless signal lamp does
not come on or is flashing
∗
Main switch defective
◊
Call the service centre *
The yellow signal lamp does not
come on or is flashing
∗
Thermostat defective
◊
Call the service centre *
The green signal lamp does not
come on or is flashing
∗
Thermostat defective
◊
Call the service centre *
* Important:
If you call the customer service dept,
you must give the following information:
Example:
- Type of fryer
- Unit no.
- Volts, amps, kilowatts
- V250
- U253A111K3
- 3x415V, 10.5A, 7.5kW
You will find this information on page 1 of these instructions and on the fryer rating plate.