valent ERC-M Скачать руководство пользователя страница 20

ERC-M Manual 
Part number:486437 
Rev. 1 
November 2023

Contact Us

Technical Support and Service

800-789-8550
[email protected]

Valent Dedicated Outdoor Air Systems

60–28th Avenue North 
Minneapolis, MN 55411
Main: 612-877-4800

More Information

Unit Schematics

For configuration and connection questions, see the schematics that shipped with your unit. They can typically 
be found attached to the main control panel door. 

Mechanical and Controls Manuals

Find current mechanical and controls manuals here: www.valentair.com/resources

© 2023 Valent 
Continuous product improvement is a policy of Valent; therefore, product 
functionality and specifications are subject to change without notice. 
For the most recent product information visit the product website.

Содержание ERC-M

Страница 1: ...d 1 Follow all local electrical and safety codes as well as the National Electrical Code NEC the National Fire Protection Agency NFPA where applicable Follow the Canadian Electrical Code CEC in Canada...

Страница 2: ...preconditioned air is typically mixed with return air going back to the air handler for final conditioning Table of Contents General Safety Information 1 Unit Overview 2 Receiving Handling Storage 3 D...

Страница 3: ...nt condensation Remove any accumulations of dirt water ice or snow and wipe dry before moving to indoor storage To avoid condensation allow cold parts to reach room temperature Leave coverings loose t...

Страница 4: ...cessary If the unit is to be mounted on its side Reference the Mounting Options sections of this IOM then service clearance should be on the electrical input side Access Panel Locations Outdoor and ex...

Страница 5: ...plugs in the holes where the bolts were removed from in Step 6 Step 8 Position the blowers to line up with the desired discharge location The motor needs to be on the discharge end of the blower and...

Страница 6: ...ed Hanging Vibration Isolator Assembly Side Discharge End IMPORTANT The ERC M unit can be hung in any orientation The installation contractor is responsible for safely mounting the unit to provide app...

Страница 7: ...Wheel Dia 1 Fan Wheel Dia n n R o tation R o tation Length of Straight Duct GOOD POOR GOOD POOR GOOD POOR Turning Vanes SYSTEM EFFECT FACTOR CURVES FPM X 100 OUTLET VELOCITY 0 5 10 15 20 25 30 35 40 4...

Страница 8: ...tion and frosting on the energy recovery core Frost Control is a selectable timer control that will prevent frosting Frost control uses a Therm O Disc P N 314886 T O D 60T11 L15 10F mounted in the out...

Страница 9: ...9 Energy Core Ventilator Mounting Wiring HOA Controller Mounting HOA Wiring ERV Control PCB GPN 387192...

Страница 10: ...nts are swapped slide SW1 switch on ERV PCB A and B motors to reverse Agency Approval UL E479135 Conditions of Acceptability 1 ERV Controller must be mounted in a suitable end use enclosure 2 Load mot...

Страница 11: ...ate 0 10V Motor command Voltage at Motor Motor command voltage must be than 2 00V Validate Frost control is not activated Check SW1 Inlet Outlet switch B Motor does not turn ON No contact closure betw...

Страница 12: ...No ___________________________________ Unit Serial No _____________________________________ Start Up Date ____________________________________ Start Up Personnel Name __________________________ Start...

Страница 13: ...ower to the ERC M prior to inspection or servicing Failure to comply with this safety precaution could result in serious injury or death Improper installation adjustment alteration service or maintena...

Страница 14: ...order to maintain optimum sensible and latent energy transfer In reasonably clean environments such as schools offices or retail stores the energy recovery core should be inspected annually and cleane...

Страница 15: ...motor will still not rotate the motor will not attempt to start again until power is cycled Thermal Protection The motors will have an internal thermal protection which electronically regulates the R...

Страница 16: ...ngs Tighten collars and fasteners Wheel out of balance Clean replace or rebalance Low airflow cfm Fan speed too low Increase fan speed Dirty filters or energy core Replace filters and or follow the cl...

Страница 17: ...____________________ _________________________________________________ _________________________________________________ Date____________________Time______________ AM PM Notes ________________________...

Страница 18: ...____________________ _________________________________________________ _________________________________________________ Date____________________Time______________ AM PM Notes ________________________...

Страница 19: ...____________________ _________________________________________________ _________________________________________________ Date____________________Time______________ AM PM Notes ________________________...

Страница 20: ...and connection questions see the schematics that shipped with your unit They can typically be found attached to the main control panel door Mechanical and Controls Manuals Find current mechanical and...

Отзывы: