Valence RT Скачать руководство пользователя страница 7

 

 

Performance may vary depending on, but not limited to cell usage and application. 
If cell is used outside specifications, performance will diminish.    All specifications 
are subject to change without notice. All information provided herein is believed, 
but not guaranteed, to be current and accurate. Copyright © 2005-2008 Valence 
Technology, Inc.   

Revision Date October 2008

12303 Technology Blvd., Suite 950, Austin, TX 78727, USA 
Phone (888) VALENCE or +1 (512) 527-2900, Fax +1 (512) 527-2910 
 
Unit 63 Mallusk Enterprise Park, Mallusk Drive, Newtownabbey, UK 
Phone +44(0) 28 9084 5400, Fax +44(0)28 9083 8912 
 
Email: 

[email protected]

, Web site: 

www.valence.com

 

 

3.

 

B

EFORE 

Y

OU 

S

TART

 

Please read all the safety information provided in this document prior to installing and/or 
operating the battery. 
 
The U-Charge

®

 

RT power system should be professionally installed and handled. Please contact 

Valence Customer Support for free consultation if you have any questions about the handling, 
operation and safe use of this battery before proceeding further.   

 

CAUTION: Performing any of the following actions will immediately void your 
warranty on the product and could lead to a potentially dangerous situation. 

 

1.  Breaking the lid and exposing the circuit boards and battery assemblies. 
2.  Puncturing or otherwise physically damaging the battery casing, circuit boards, battery 

cells or any other part of the battery mechanism. 

3.  Operating the battery in an environment where the temperature is higher than 60°C 

(140°F). 

 
If you believe that in the course of using the U-Charge

®

 power system, you will conflict with any 

of the above listed conditions or any other safety precautions listed in this manual, please 

DO 

NOT

 proceed any further and contact Valence Technology immediately for guidance and 

information. 
 

3.1 General information 

Please inspect each battery carefully. Report any damage from shipping to Valence Technology, 
Inc. immediately. 

 

 
Verify in advance that the U-Charge

®

 RT power system fits your specific requirements.   

U-Charge

®

 RT Series batteries are designed for 12, 24, 36 or 48 Volt systems.    Do not use if 

your system requires more than 4 batteries connected in series.    The U-BDI is required for 
systems that are 24-48V for proper inter-module balancing. The U-Charge

®

 RT power system 

can be charged by most lead acid chargers set for Gel/AGM setting. 
 

 

12 Volt System  24 Volt System  36 Volt System  48 Volt System 

Recommended 
Charge 
Voltage 

14.6 Volts 

29.2 Volts 

43.8 Volts 

58.4 Volts 

Max allowed 
Charge before 
auto 
disconnect 

15.2 Volts 

30.4 Volts 

45.6 Volts 

60.8 Volts 

Содержание RT

Страница 1: ...U CHARGE RT BATTERY MODULE USER S GUIDE Please read all contents of this User s Guide prior to the installation of U Charge RT energy storage system...

Страница 2: ...able 2 Contents and tools required 8 5 Installation 8 5 1 Tips 8 5 2 Installation of U Charge RT Battery into a 12 V System 9 5 3 Installation of up to 4 batteries in Series 10 Table 3 Pin out of the...

Страница 3: ...guaranteed to be current and accurate Copyright 2005 2008 Valence Technology Inc Revision Date October 2008 12303 Technology Blvd Suite 950 Austin TX 78727 USA Phone 888 VALENCE or 1 512 527 2900 Fax...

Страница 4: ...Mallusk Drive Newtownabbey UK Phone 44 0 28 9084 5400 Fax 44 0 28 9083 8912 Email sales valence com Web site www valence com 1 CONTACT INFORMATION Customer Support 8 AM to 5 PM CST 1 888 VALENCE USA...

Страница 5: ...kaging International law dictates that the batteries are shipped under UN 3090 Class 9 rules for hazardous goods dangerous materials Burn Hazard Abusive operation of the battery e g overcharge crush p...

Страница 6: ...ct your local regulatory authorities for more information Do Not include battery with lead acid battery recycling Your battery should not be thrown in the trash Shock Hazard Labels may be located on o...

Страница 7: ...on 1 Breaking the lid and exposing the circuit boards and battery assemblies 2 Puncturing or otherwise physically damaging the battery casing circuit boards battery cells or any other part of the batt...

Страница 8: ...packs in a series ensure that they are fully charged or at least all the same state of charge prior to installation This will enable the maximum capacity to be realized from your pack 4 CONTENTS TOOL...

Страница 9: ...2900 Fax 1 512 527 2910 Unit 63 Mallusk Enterprise Park Mallusk Drive Newtownabbey UK Phone 44 0 28 9084 5400 Fax 44 0 28 9083 8912 Email sales valence com Web site www valence com connection These b...

Страница 10: ...e RT power system into a vehicle device If a U BDI is used connect it to the female communication connector or wire If not leave the communication connector or wires disconnected 5 3 Installation of u...

Страница 11: ...e com Web site www valence com Figure 4 Installation of U Charge RT power systems in Series A RS 485 bus is used as the communication method between a U Charge RT power system and its U BMS Each batte...

Страница 12: ...2 Charging the Battery For normal charging use a battery charger that has an output of 20A or less until the Voltage reaches Recommended Charge Voltage and then automatically tapers the current down t...

Страница 13: ...chnology for the recommended charging profile for your system If a U BDI is attached the 10 bar LEDs will light up according to the system s state of charge Once any cell has reached 3 65V the yellow...

Страница 14: ...once the cell voltage increases over 2 7V during charge 7 2 Charge Control When the modules are charged to the point where any single cell block reaches its maximum value 3 9V the battery will prohibi...

Страница 15: ...erminals female threaded 1 4 20 1 4 20 M8 x 1 25 M8 x 1 25 Specific energy 73 Wh kg 84 Wh kg 81 Wh kg 85 Wh kg Energy density 66 Wh l 110 Wh l 126 Wh l 140 Wh l Max cont current 30 A 30 A 30 A 30 A Ma...

Страница 16: ...95 non condensing Water dust resistance IP56 Shock and vibration IEC61960 DIN VG96 924 Certifications FCC Class B CE UL1642 cells Shipping classification UN 3090 Class 9 Table 6 U Charge RT Specificat...

Страница 17: ...s a 10 segment State of Charge SOC LED indication bar and battery status indicators The U BDI also monitors and controls battery to battery balance for multiple battery systems Please refer to separat...

Страница 18: ...ee NOTICE below The individual cell voltages can be viewed with the RT Monitoring and Diagnostic Kit Valence part number 1004236 NOTICE If the battery was charged at a higher current than 1A and the l...

Страница 19: ...to have dents discoloration or appears to be damaged in any way DISCONTINUE USE IMMEDIATELY Please contact Valence Technology for assistance with evaluating the product for continued usability 10 2 Vo...

Страница 20: ...iodically and recharge if it is at or below 12V Monthly tests are recommended Store in an open well ventilated dry clean area between 40 C and 45 C 40 F and 113 F for maximum life Self discharge is ac...

Страница 21: ...who is certified to handle and prepare products that have been designated as Dangerous Goods for shipment 4 Ship under regulations UN3090 Class 9 Dangerous Goods NOTE The U Charge RT power system is...

Страница 22: ...local requirements when disposing of lithium ion batteries Commonly available methods include disposal and collection by a licensed waste company or recycling Some states and communities have program...

Страница 23: ...year from the date of original retail purchase This warranty applies to the original purchaser the Customer only and is non transferable During the Warranty Period should the Product in Valence s opi...

Страница 24: ...rm of one 1 year from the date of original retail purchase or in the event relevant state law requires an implied warranty term exceeding one 1 year for the briefest term allowable under relevant stat...

Отзывы: