Figure 4: Installation of U-Charge
®
RT power systems in Series.
A RS-485 bus is used as the communication method between a U-Charge
®
RT power system
and its U-BMS.
Each battery contains one male and one female connector which are wired in
parallel to make it possible to daisy-chain communication cables. Figure 5 and Table 3 describe
the pin-out of the two 5-pin M12 connectors:
Me chanical Ke y
1
2
4
3
5
Figure 5. Female type M12 connector
Pin Signal
Name
Pin Type
Description
1
N/A N/A Shield
2
VCC (+5)
Power
Power supply for the RS-485 transceiver
3
GROUND
Power
Ground for the RS-485 transceiver
4
B(+)
Signal
B signal from the RS-485 transceiver
5
A (-)
Signal
A signal from the RS-485 transceiver
Table 3: Pin-out of the RS-485 communication ports in U-Charge
®
RT power system