CAPTESTER
OPERATION MANUAL
AUS
1300 734 253 NZ 0800 734 253
10
TEST REPORT
Here you can create test reports. You can mark the desired points of the graph documenting the test details, making notes,
etc.
To make the report:
1.
Fill the A, B, D, F, E field of the test report.
2.
Select the type of marker you would like to place (Voltage or Current).
3.
With the RIGHT mouse button, you can place Voltage or Current markers to any point of the graph.
4.
Print the test report.
5.
Close the test report.
Moving the Marker
Position the pointer to the marker, and drag the marker while keeping the left button pushed.
Deleting the Marker
Position the pointer on the marker and push the RIGHT mouse button.
TEST WINDOW
GRAPH SETTINGS
The measurement window contains a graph setting icon. If you click on the icon, you will have the visisble possibilities.
–
Visible:
what you want to be visible/invisible (current, voltage)
–
Scaling Boxes:
you can turn the scaling boxes off or on at the side of the graph
–
Grid:
you can turn the grid on or off
–
Axis Scale:
you can set the step values on the axes (not released at present default is 1)
–
Vertical Marker:
you can set the stepping values of the vertical marker
1.
Company logo (you can import a BMP logo by pressing the right button).
2.
Company Information
3.
Test Details.
4.
Test Parameters.
5.
Comments:
–
Print the test reports (first you will see the preview)
–
Save the graph as BMP
–
Export test report in Microsoft Word format
–
Copy graph to clipboard
–
Help
–
Close
–
Select voltage or current: define if you would like to place the voltage or current
–
Voltage values: voltage value at the actual cursor position
–
Current value: Current value at the actual cursor position
–
Time value: Time value at the actual cursor position