background image

BT IBT612

OPERATION MANUAL

AUS

  

1300 734 253     NZ  0800 734 253

6

5. 

When ready, press and hold the test button (approx. 1 sec.) to test the Ah capacity available in the battery.

PRESS TO TEST

6. 

Record the Ah reading obtained onto a label for future reference.

TESTING Ah...

7.2Ah

7. 

If required, press the test button again to verify the Ah reading obtained.

Capacities below 8Ah will be displayed with a decimal point up to 7.9Ah. Capacities above will 

be rounded up from 8Ah to 99Ah. Capacities over 99Ah will be displayed as ‘OVER 100Ah’.

 

IMPORTANT!

8. 

Recharge or replace when the Ah capacity available in the battery falls below 65% of the stated battery Ah capacity. 

NOTE! Ah capacity can be affected by the batteries temperature and state of charge (SOC).

FLAT BATTERY

9. 

This message indicates low battery voltage or Ah capacity. Recharge or replace the battery and re-test.

HIGH VOLTAGE

10. 

This message indicates that the input voltage exceeds 15V.

REMOVE IMMEDIATELY!

Содержание 612

Страница 1: ...AUSTRALIA 1300 734 253 sales valen com au www valen com au NEW ZEALAND 0800 734 253 sales valen co nz www valen co nz OPERATION MANUAL INTELLIGENT BATTERY TESTER 612...

Страница 2: ...ry increasing growth the Lake Cargelligo Head Office moved into a brand new purpose built facility in 2012 In 2015 Regal Electro successfully completed its rst ENLiFEN Energy Storage Optimiser ESO pro...

Страница 3: ...done Upbeat Positive Attitude If our employees have a positive attitude and constantly strive to give your best effort eventually we will overcome our immediate problems and nd you are ready for grea...

Страница 4: ...re of the battery technology use this calibration setting as the default To measure the Ah capacity available in standby SLA batteries adjust the Ah calibration control with a screwdriver to the 0 Ah...

Страница 5: ...teries adjust the Ah calibration control to the Ah CAL position OPERATION 1 Observe polarity connect the test lead clips exactly as shown for the types of battery terminals pictured 2 After connection...

Страница 6: ...displayed with a decimal point up to 7 9Ah Capacities above will be rounded up from 8Ah to 99Ah Capacities over 99Ah will be displayed as OVER 100Ah IMPORTANT 8 Recharge or replace when the Ah capacit...

Страница 7: ...age required is 2 3VPC which is 6 9V for a three cell 6V battery and 13 8V for a six cell 12V battery Voltage tolerance is 2 2VPC min and 2 4VPC max 4 Recharge immediately to prevent damage caused by...

Отзывы: