40
FP16
– Saint-Laurent - Installation and Operation Manual
1.5.5
Angled Wall Radiation Shield
When passing through a combustible wall with the chimney at a 30
or 45
angle (30
or 45
in Canada and
30
only in the USA), an angled firestop
(A)
or wall radiation shield must be installed. Only one is required.
Follow the chimney manufacturer’s installati
on instructions.
In cold climate locations, it is recommended that you use the insulated wall radiation shield since it will
maintain the home’s thermal barrier
.
1.5.5.1
Universal Offset Support
This support is used to support the chimney above an offset. When the chimney offset is used to pass
through a wall, this support may be used on the wall to support the chimney. For offset support installation,
refer to the instructions provided with the support by the chimney manufacturer. Many manufacturers will
provide the maximum height of chimney that can be supported by the support. Make sure you respect
those parameters.
1.5.6
Universal Roof Support
This support has three possible uses:
1.
It must be used on a roof to support the chimney.
2.
It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
3.
It may be used on a floor, ceiling or roof as a supplementary support.
For roof support installation, refer to the instructions provided with the support by the chimney
manufacturer. Many manufacturers will provide the maximum height of chimney that can be supported by
the support. Make sure you respect those parameters.
A
INSULATED WALL RADIATION SHIELD
B
GYPSUM BOARD
C
INSULATED WALL