10
3.
As illustrated in Figure 6 and 7, position the heat shield (C) between the spacers
previously installed with the folds facing up. Align the holes of the shield with the
ones of the left and right spacer and secure it with 4 screws (B).
Figure 6
Figure 7
3.3
Fire Baffles Installation
Your fireplace FP7-LM contains two fire baffles. In order to protect them during
transportation, the small fire baffle (D) is located at the bottom of the combustion chamber,
while the largest (E) is in the box in front of your fireplace door. Note that in order to inasall
the small fire baffle (D) properly, it should lean against the back of the chimney throat, as
shown in Figure 3.3 A. For the installation of the biggest fire baffle (B), it must be positioned
as shown in Figure 3.3 B and lean against the front of the chimney throat.
Follow these steps to install the fire baffles:
1.
To install the first fire baffle (D), hold it in your hands with the narrowest part towards
the back of the unit (Figure 3.3 A).
2.
Move the piece up to the top bracket at the back of the fireplace throat, taking care to
avoid the bracket of the front fire baffle (Figure 3.3 C).
3.
Place the baffle on its brackets and make sure it is leaning against the back of the
chimney throat (Figure 3.3 D)
4.
To install the front fire baffle (E), hold it in your hands with the narrow end toward the
back of the fireplace (Figure 3.3 B).
5.
Move the piece up, making sure to keep it close to the front wall of the chimney throat
for easy maneuverability (Figure 3.3 E).
6.
Once one side has exceeded its bracket, lean it against the side and front wall of the
chimney throat for easy maneuverability. Then rotate the piece so that the other side is
also above its support (Figure 3.3 F).
7.
Place the baffle on its bracket and slide it horizontally to center it (Figure 3.3 G).
Make sure the fire baffle is leaning against the front of the chimney throat.
Содержание FP-7-LM ANTOINETTE
Страница 11: ...11 Figure 3 3 A Figure 3 3 B Figure 3 3 C Figure 3 3 D Figure 3 3 E Figure 3 3 F Figure 3 3 G D E...
Страница 16: ...16 Figure 13 Figure 14...
Страница 17: ...17 Figure 15...
Страница 18: ...18 Figure 16...
Страница 19: ...19 Figure 17 Insulated chase construction...
Страница 20: ...20 Figure 18 Spacers must be installed...
Страница 22: ...22 Facing With the Narrow Overlap Figure 19...
Страница 23: ...23 Facing With the Masonry Trim Figure 20...
Страница 26: ...26 Figure 23...
Страница 28: ...28 Figure 24 Figure 25...
Страница 39: ...39 EXAMPLE OF TYPICAL CHIMNEY INSTALLATION Figure 33...
Страница 41: ...41 Figure 34 Figure 35...