Valcom VIP-851-25-IC InformaCast Скачать руководство пользователя страница 4

 

947586 

 
 
 
 
 
 
 
 

VIP-851-25-IC Rear View 

 
 
 
 
 
 
 
 
 

VIP-851-70/100-IC Rear View 

 

 
Setup 

The VIP-851-25-IC and VIP-851-70/100-IC will 
automatically acquire an IP address (using DHCP) 
and connect to the InformaCast server when 
connected to the network and powered up.  
Information specific to your application will need to 
be programmed into the InformaCast server.  Refer 
to the InformaCast documentation for further 
Information. 
 

Supervision 

The VIP-851-25-IC can provide wiring supervision 
capability of both the 25V and LINE outputs.  The 
VIP-851-70/100-IC can provide this capability only 
on the LINE output. Supervision must be enabled in 
programming.   For supervision, the speakers 
and/or devices connected to these outputs must be 
supervisory compatible and there must be an end of 
line resistance of 4700 ohms.  Two 4700 ohm 
resistors are included with the unit for convenience.  
The unit will monitor the output pair(s) for opens or 
shorts if so optioned.  Wire monitoring is temporarily 
disabled on the 25V output while it is active. The 
output relay can also be programmed for 
supervision to provide additional notification of 
faults.  If programmed for supervision, the relay will 
energize during power up (NO will short to COM 
and NC will open to COM) and will de-energize (NC 
will short to COM and NO will open to COM) if the 
unit has lost power, the PoE+ FAULT LED is lit or if 
the SUPERVISION FAULT LED is lit solid or 
blinking.  Syslog messages are also generated by 
the VIP-851 indicating system supervision activity.   
 
Additional equipment may be required.  Contact 
Valcom Technical Support for more information.

Status Indicator Lights 

The VIP-851 has status indication lights on the front 
panel:  

 

STATUS: 

Flashes during normal operation and  

solid during system startup. 
 

PoE+ FAULT: 

Indicates the lack of correct PoE+ 

connectivity or an incorrect configuration of the 
power available at the network port. 

 
SUPERVISION FAULT: 

Indicates a connectivity 

problem on either the LINE (VIP-851-25-IC and 
VIP-851-70/100-IC) or 25V connections (VIP-851-
25-IC only).  The activity for this LED is configured 
using the IP Solutions Setup Tool.  The Supervision 
LED can be configured for “Ignore”, “Track” or 
“Historical” for monitoring both or either the 25V 
output (Speaker Faults) and the Line output: 
 

LED OFF

 – 

No problem with any output (or 

programmed for “Ignore”).

 

LED ON SOLID

 – 

Existing problem with one or both 

of the monitored outputs (in either “Track” or 
“Historical” modes).

 

LED BLINKING

 - (only blinks if monitoring is set for 

“Historical”) – indicates an intermittent problem on 
one or both of the outputs that has been resolved. 
 

Note:  If the LED is blinking, the monitoring for 
“Historical” is reset by software (via VIP-102B 
tool), power down reset of the VIP-851 or with 
the “factory restore” front panel button. 

 
Green LED:  

(Link) Indicates Ethernet connection 

when illuminated. 

 
Yellow LED: 

(Activity) Indicator flashes to indicate 

network activity. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Отзывы: