Valcom VIP-851-25-IC InformaCast Скачать руководство пользователя страница 3

 

947586 

 

Wall

:  Attach mounting brackets as shown in Figure 

1, and secure to wall with proper hardware (not 
included).

 

 
 
 
 
 
 
 
 
 

               

 

Figure 1.  Mounting 

 

Power Connections 

The preferred method of powering a VIP-851 is via 
a Power over Ethernet Plus (PoE+) switch meeting 
the 802.3at specification.   
 
If the rear panel barrel connector is used for power, 
the preferred power supply is a Valcom VP-1124D 
or larger power supply. 
 
Make all required signal connections before 
applying power to the unit.  If powering via 802.3at, 
make sure all signal connections via the back panel 
are made then connect the VIP-851 to the Ethernet 
switch.  
 
If power is supplied via the barrel connector, make 
sure all signal connections are secure.  Attach the 
unit to the network via the front panel RJ-45 
Ethernet connector.  Apply power by plugging the 
power supply into the VIP-851 via the barrel 
connector on the rear of the VIP-851. 
 

Network Connection 

The VIP-851 has one RJ-45 network connector on 
the front panel.  Use a standard Ethernet patch 
cable to connect the VIP-851 to an Ethernet switch.   
 

Signal Connections 

The VIP-851 has signal connectors on the rear 
panel: 

 

  AUX audio input 

  1 Contact Closure input 

  2 Audio outputs (VIP-851-25-IC) 

  4 Audio outputs (VIP-851-25/70/100-IC) 

  1 Form C relay output

AUX Audio Input

:  Line-level audio may be input 

via the rear panel screw terminal block labeled 
AUX.  Nominal input impedance is 600 Ohms.  
Audio connected on AUX is directed to the locally-
connected speakers (Output connections).  The 
AUX audio input is typically used for local 
background music, and will be muted during a 
page.  

The supervision feature of the 25V 

speaker output is disabled if using the AUX 
input for audio to locally-connected 25V 
speakers. 

 
Contact Closure Input: 

Contact closure input 

labeled CC is provided for connecting an external 
contact (relay, switch, etc.) to trigger actions in the 
VIP-851.  The input can be programmed to 
remotely activate a relay on another Valcom device 
across the network and send a syslog message. 

 
Audio Outputs:  

Two or four audio outputs are 

available, depending on model.  The VIP-851-25-IC 
provides two outputs, LINE and 25V.   
The VIP-851-70/100-IC provides four outputs, LINE, 
25V and 70V or 100V.  The LINE output provides a 
line-level signal suitable for driving up to 40 Valcom 
self-amplified speakers or other devices requiring a 
line-level source.  The LINE output may be used in 
combination with the amplified outputs.  The 
amplified outputs provide up to 20 watts of audio 
power suitable for driving up to a 20 watt load of  
25-volt, 70 or 100 volt speakers. 25-volt speakers 
will connect to the 25V terminals.  70-volt speakers 
will connect to the COM (common) terminal and the 
70V terminal.  100-volt speakers will connect to the 
COM terminal and the 100V terminal.  Do not mix 
25V, 70V and 100V speakers on the same  
VIP-851-70/100-IC. 

 
Relay Output: 

Access to the form C relay is 

provided via a three pin screw terminal block. The 
relay is labeled K1. The relay is brought out on 
three terminals.  The common contact is the middle 
terminal with the normally closed contact labeled 
NC and the normally open contact labeled NO.  
Relay contacts are rated for 1A @ 24VDC. 
 
 
 
 
 
 
 

VIP-851 Front View 

 
 
 
 
 