1
947546
ISSUE 2
VIP-804B
QUAD NETWORK AUDIO PORT
INTRODUCTION
The VIP-804B Quad Network Audio Port enables
voice access to four zones of one-way paging over
an IP network, allowing page zones to be extended
anywhere network connectivity is available. The
VIP-804B can be programmed as a SIP (Session
Initiation Protocol) device with four identities (one
per audio channel) for connectivity to virtually any
Voice over IP (VoIP) telephone system.
SPECIFICATIONS
Features
4 Audio Outputs or Inputs
4 Form A relay contacts
4 Contact Closure Inputs
4 SIP identities for registering to a SIP
telephone system
RJ-45 jack for network connection
Front panel activity LED
Provides audio for up to 40 Valcom one-way
amplified speaker assemblies per zone
Output control contact closure provided during
paging output
Contact closure or VOX operation of audio
inputs
VM-186 RJ-45 Connector provided for audio
and relay interface
Page with music output, music mutes during
page
AUX audio input via RCA Jack for background
music
Compatible with 25 or 70 Volt amplifiers
2.5mm jack for optional DC power
Power over Ethernet (PoE) 802.3af compatible
Dimensions/Weight
1.72
” H x 7.00" W x 11.88" D
(4.36cm H x 17.78cm W x 30.18cm D)
Weight: 2.5 lbs. (1.13 kg)
Nominal Specifications
Input Impedance:
600 Ohms
Input Level:
-10dBm nominal
Voice Switch Sensitivity:
-21dBm
AUX Input Impedance:
8 to 600 Ohms
AUX Input Level:
-10dBm nominal
Output Impedance:
50 Ohms
Output Level:
- 10dBm nominal
Relay Current:
1 AMP @ 24VDC
Nominal Power Requirements
Via back panel barrel connector:
Voltage:
24VDC
Current:
325mA
Via 802.3af PoE Ethernet Switch:
802.3af:
Class 3
These products are intended for use with a UL
Listed power source marked “Class 2” or “LPS”
rated 24VDC, or 48VDC (PoE).
PoE and all interconnected ITE are intended for
intra-building.
Environment
Temperature:
0 to +40° C
Humidity:
0 to 85% non-precipitating
Precautionary Designations
WARNING-To Reduce The Risk Of Fire Or
Electric Shock. Do Not Expose This
Apparatus To Rain Or Moisture.
AVERTISSEMENT - Afin de réduire les
risques d'incendie ou de décharge
électrique, évitez d'exposer le système à la
pluie ou à l'humidité.