background image

 

 

                                           

ALCOM

V

VIP-LLE

W/BL

W/O

W/GN

W/BR

900' MAX DISTANCE

CAT 3/5/6

802.3af Compliant PoE Network Port

Paging Horn 

Status
Link
Act

WHITE/BLUE

BLUE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

WHITE/ORANGE

NOT USED

Front View

VM-186

RJ45

BROWN

BLUE

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

Note: The Brown and White/brown pair should 
be twisted together and inserted into the 

connector noted on the drawing and the Green 
and White/Green pair should also be twisted 
together and inserted into the connector that is 

noted on the drawing.

Note: The screw terminals are removable. 

Gently lift away from the circuit board to 
remove. Make the necessary wire connections, 

then replace the screw terminals over the pins 
on circuit board.

Rear View with Screw Terminal Connectors

IP Paging Horn 

AUDIO OUTPUT

Rear View with RJ-45 Connector

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2 

 
 

Содержание VIP-480L

Страница 1: ...stem Features RJ 45 network connection LED Status Indicator Network activity LEDs Power over Ethernet PoE 802 3af compatible High Efficiency Class D 3 Watt Amplifier Dimensions Weight HORN 6 8 H x 8 3 W x 3 3 D 17 3cm H x 21 1cm W x 8 4cm D 2 1 lbs 0 95 kg Network Extender VIP LLE 1 30 H x 6 10 W x 6 00 D 3 51 cm H x 15 72 cm W x 13 51 cm D Weight 0 85 lbs 0 39 kg Nominal Specifications HORN Input...

Страница 2: ...tions and test the speaker for operation Using appropriate mounting screws not furnished drill and mount the flange as shown UNIVERSAL BRACKET Loosen or separate the universal bracket leaves by loosening or removing the handle and hardware Using the back leaf as a template mark the wall through the mounting holes Drill and mount to the wall using appropriate screws not furnished or mount directly ...

Страница 3: ...orkmanship under conditions of normal use and service for a period of one year from the date of shipment This Limited Warranty obligation shall be limited to the replacement repair or refund of any such defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the orig...

Страница 4: ...ite brown pair should be twisted together and inserted into the connector noted on the drawing and the Green and White Green pair should also be twisted together and inserted into the connector that is noted on the drawing Note The screw terminals are removable Gently lift away from the circuit board to remove Make the necessary wire connections then replace the screw terminals over the pins on ci...

Страница 5: ...ATE TO MOUNTING HARDWARE AND CUT OUT THE OPENING HOLDING FLEXHORN FIRMLY AGAINST A FLAT SURFACE DRILL THROUGH EACH MOUNTING BOSS AS SHOWN FLUSH MOUNTING IN A STUD WALL INSTALLED WITH MOUNTING SCREWS OR CONSTRUCTION CEMENT PENDANT MOUNTING WITH OPTIONAL CHAIN AND EYE SCREW OPTIONAL V 9805 VANDAL RESISTANT ENCLOSURE OTHER MOUNTING OPTIONS FLUSH MOUNT USING MOUNTING SCREWS C CLAMP FOR I BEAM MOUNTING...

Отзывы: