Speaker Connection 

Connect the attached wire assembly from the             
V-

CTLA 2’ x 2’ ceiling speaker to the Speaker screw 

connections on the clock circuit board. 

 

Network Connection 

The VE4122-A12 has one RJ45 network connector on 
the rear panel. Use a standard Ethernet patch cable to 
connect the unit to an Ethernet switch. 
  

 

Call Switch Connection 

For IP Speakers using Talkback functionality, a call 
switch input via screw terminals is provided.  Connect a 
momentary contact switch to Switch 1 and Ground. 

 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to up to 
40 Valcom Self Amplified Speakers in order to provide 
additional sound reinforcement in an area

.

 

 

Mute Out Connection 

The Mute Out may optionally be connected to the mute 
input of Valcom audio management systems in order to 
suspend locally originated audio during intercom 
announcements.

LED 1 and LED 2 Connection 

LED 1 (+) and LED 2 (-) is a current limited output 
designed to illuminate an optional LED. The LED is 
intended to provide visual indication of call progress.  
The LED illumination will flash when the call switch is 
pressed and will continue to flash until the call is 
answered.  The LED illumination will be solid when 
connection to the unit is established. 
 

Setup 

Information specific to your application will need to be 
programmed into the VE4122-A12 using a computer.  
The PC used for programming should be connected to 
the same subnet as the VE4122-A12.  Setup will be 
done using the IP Solutions Setup Tool.  Download the 
latest version of the free IP Solutions Setup Tool from 
the Valcom.com web site at 
www.valcom.com/vipsetuptool 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections. If a spare unit is available, substitute a 
spare unit for the suspected defective unit. 

 

Assistance in troubleshooting is available from the 
factory.  Call (877) 427-2166 and ask for Valcom 
Engineered Solutions Technical Support or visit our 
website at www.ValcomES.com. 
 
Valcom equipment is not field-repairable. Valcom, Inc. 
maintains service facilities in Roanoke, VA.  Should 
repairs be necessary, attach a tag to the unit clearly 
stating your company name, address, phone number, 
contact person and the nature of the problem. 
Send the unit to: 

 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056 

 

WARRANTY 

Warranty information may be found on our website at 
www.valcom.com/warranty. 

          

 
 
 
 
 
 

 
 