background image

FCC Information 

This equipment has been tested and found to 
comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide 
reasonable protection against harmful 
interference when the equipment is operated 
in a commercial environment.  This 
equipment generates, uses and can radiate 
radio frequency energy and if not installed 
and used in accordance with the instruction 
manual, may cause harmful interference to 
radio communications.  Operation of this 
equipment in a residential area may cause 
harmful interference in which case the user 
will be required to correct the interference at 
his own expense. 

 

 

Installation/Connection 

Cabling 

Category 3 or 5 twisted pair cable is 
recommended for all Valcom distributed 
amplified paging installations.  Screw terminals 
are provided for the basic connections.  RJ45 
jacks are provided for chaining multiple V-9964 
units together.  Removing the narrow right side 
panel of the V-9964 provides access to controls, 
connections and option switches.  To remove 
the panel, loosen the two screws holding the 
panel in place and lift the panel. 

 

Mounting 

The V-9964 may be wall mounted or rack 
mounted in a standard 19 inch equipment rack 
using the brackets included. 

 

Connections 

See Figure 1 for a connection diagram. 

 

Tip 1,  Ring 1 

INPUT 1 is the normal Primary or Call Stacker 
system input.  Connects to a Loop Start Trunk 
Port, 600 Ohm Page Port or some Valcom Page 
Controls.  Do 

not

 connect to a C. O. Line.

 

 

Control Input 1

 

Provides contact closure activation when using a 
Page Port. 

 

Tip 2, Ring 2 

INPUT 2 is the Override page or Call Stacker 
line two input.  If desired, connect this to a 
second Loop Start Trunk Port or Page Port. 
Do 

not

 connect to a C. O. Line. 

Control Input 2

 

Provides contact closure activation when using a 
Page Port. 

 

Background Music Input

 

Connection for external line level music source 
(Example: V-2952, FM Tuner). 
 

NOTE

If  using multiple V-9964 units in a 

chained configuration, all speakers must 
connect to the output of the last unit  in the

 

chain.

 

 
Line Out 

Output connections to Valcom amplified 
speakers or 70 Volt amplifier Aux input. 

 

Loop Out

 

Connects to Tip and Ring input on a Valcom 
multi-zone page control unit. 

 

Expansion In 

RJ45 connection from the previous V-9964 in a 
chained configuration. 

 

Expansion Out 

RJ45 connection to the next V-9964 in a chained 
configuration. 

 

Abort 

To abort a message during play, connect an 
external relay contact across the two abort 
terminals. 

NOTE: To abort a message during the record 
sequence, press any DTMF button on the dial 
pad of the access telephone. 
 
Relay Closure Outputs 
(PLAY) PLYSW and PLYMK 

Normally open relay contact that closes while a 
message is being broadcast

(RECORD) RECSW and RECMK 

Normally open relay contact that closes while a 
message is being recorded. 
 

(BUSY) BSYSW and BSYMK 

Normally open relay contact that closes when 
the unit cannot accept any more messages. 

 

Switches and Controls 

NOTE: (OFF-Left)  (ON-Right) 

Refer to figure one for locations. 

 
 