WIRING INSTRUCTIONS:

 

Place a check by each step as it is completed. 
__  1. 

Connect Tip of the first Central Office line or 
PABX station number to the V-9936A pin 1 
(C.O. 1 Tip). 

__  2.    Connect Ring of the first line or station to 

pin 16 (C. O. 1 Ring). 

__  3. 

Connect Tip of line 2 to pin 2 and connect 
Ring of the line to pin 17. 

__  4.    Connect Tip of line 3 to pin 3 and connect 

Ring of the line to pin 18. 

__  5.    Connect Tip of line 4 to pin 4 and connect 

Ring of the line to pin 19. 

__  6. 

Connect Tip of line 5 to pin 5 and connect 
Ring of the line to pin 20. 

__  7. 

Connect Tip of line 6 to pin 6 and connect 
Ring of the line to pin 21. 

     8. 

If using multiple V-9936A's: 

__(a)  

Connect a group of 6 lines or station 
numbers to each V-9936A as in steps 1-7. 

__(b)  

Connect a wire from pin 8 (Expansion) of 
the main unit to pin 8 of each additional 
unit. 

__  9. 

NOTE: Complete the wiring and testing of 
the paging system and properly adjust all 
volume controls before continuing. 

__10. 

If using Valcom paging speakers: 

__(a)  

Note the location of the speaker wires on 
the page control unit and remove them. 

__(b)  

Connect the speaker wires removed in (a) to 
pins 11 (Tip) and 26 (Ring) of the V-9936A. 

__(c)  

Connect V-9936A pins 13 (Tip) and 28 
(Ring) to the page control locations noted 
in (a). 

NOTE:  If the page control unit provides background 
music input, the page out terminals may be connected 
to the BGM input and the speakers connected directly 
to the Page Control Unit. 
    11. 

If using a high power amplifier: 

__(a)  

Disconnect the paging signal wires from the 
INPUT of the amplifier and connect them to 
the V-9936A pins 13 and 28. 

__(b)  

Connect V-9936A pins 11 (Tip) and 26 
(Ring) to the amplifier INPUT. 

__  12.  Set the speaker select switch to Lo Z. 
__  13.  If adding a night switch, connect it to pins 9 

and 24. 

__  14.   Plug in power supply  (See power 

connection section). 

__  15.  Dial a line connected to the V-9936A.  When 

it starts ringing, adjust the V-9936A volume 
control to the desired level. 

 

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

24VDC
POWER
SUPPLY

-

+

NIGHT SWITCH

SPEAKERS

V-9936A

FIGURE 4 -  RINGING OVER PAGING CONNECTIONS

AUDIO OUT

PAGE CONTROL UNIT

Central
Office or
Station
Lines

6

1

 

Содержание V-9936A

Страница 1: ...Central office lines PABX station numbers Phone system night ring relay Features Monitors six lines Units may be multiplied for additional lines Provides interrupted electronic warble tone output for...

Страница 2: ...cted to one zone of a Valcom One way or Talkback Paging System or to the INPUT of a high powered amplifier The following components are required V 9936A C O Ring Units 1 per 6 lines VP 624B 24VDC Powe...

Страница 3: ...EWAY OPENING TO WALL PLATE AND JUNCTION BOX WIRE TIE LOOP WIRE TIE USED TO BUNDLE WIRES ENTERING AND LEAVING TERMINAL AREA SNAP LATCH FOR COVER 155 DIA HOLES FOR MOUNTING TO SINGLE OR DOUBLE GANG JUNC...

Страница 4: ...power supply __ b Reverse connections on V 9936A pins 29 GND and 30 24VDC __ c Go to step 6 __ 6 Unplug power supply 15 30 1 16 HiZ LoZ V 9936A Do Not Adjust Speaker Select Switch Volume Control Rever...

Страница 5: ...Tip of speaker to pin 11 __ b Connect Ring of speaker to pin 26 __ c If using one way amplified speaker assemblies __ 1 Connect the 24VDC speaker lead to V 9936A pin 10 __ 2 Connect the Ground speaker...

Страница 6: ...s __ a Note the location of the speaker wires on the page control unit and remove them __ b Connect the speaker wires removed in a to pins 11 Tip and 26 Ring of the V 9936A __ c Connect V 9936A pins 1...

Страница 7: ...ct pins 11 and 26 to a line level input on the amplifier __ 4 If using a night switch connect it to pins 9 and 24 When the switch is closed the V 9936A is disabled __ 5 Set speaker select switch to th...

Страница 8: ...oting is available from the factory When calling you should have a VOM several clip leads a telephone test set available and be calling from the job site Call 540 563 2000 and ask for Technical Suppor...

Страница 9: ...e will cover minor repairs Major repairs will be subject to additional charges for parts and labor This warranty is in lieu of and excludes all other warranties expressed or implied and in no event sh...

Отзывы: