CLOCK TYPE CODES

Type #

Description

Figure #

1
1
2
3
4
4
5
6
7
8
9

10
11
12
13
14
15
16

17
18
19
20
21
22
23
24

Valcom Sync-wired 12-hour
TED Systems A1000M & D1000
Simplex/Edwards Sync-wired 24-hour
Simplex Generator Start (12 hour & Hourly Correction)
Simplex/IBM Impulse, 3 Wire, 58th or 59th Minute
Simplex Impulse, 2 Wire, 59th Minute Ref
Utility Impulse 12VDC or 24VDC (Non-Corrective)
European Duplex Reverse Polarity (24VDC or 48VDC)
Honeywell Faraday (1300 Series) / Cincinnati (D Synchronous)
National Time Hourly
Rauland, National Time, 12 Hour Correction
Stromberg (Synchronous, 56th Minute Ref, Electronic)
Simplex, dual Motor, 45th Minute Ref
Simplex, dual Motor, 59th Minute Ref
Cincinnati D6 (Impulse, 12 Hour Correction)
Cincinnati D3 (Impulse, 59th Minute Ref)
Stromberg (Impulse, 58th Minute Ref)
Standard Electric Time FMT-Dual Motor Couch C542014 through
C452019; C452133 through 452145
Standard Electric Time, AR2, Impulse, 59th Minute ref
Standard electric Time, AR3A, Impulse, 60th Minute Ref
Dukane 24A, 24 Hour Correction
Dukane 240, 24 Hour Correction
Dukane 240, 12 Hour Correction
Standard Electric GR Sync 12 Hour Correction
Simplex 1.8” digital 12 Hour
Simplex 1.8” digital 24 Hour

3

17

3
9

13
14
12
11

3
3
3
3
5
5
6
6
6
4

8
7

10

3
3
3

15/16
15/16

Simplex 6333 Series LED Load Chart

14 AWG

16 AWG

18 AWG

20 AWG

22 AWG

24 AWG

2

4960’

3109’

1956’

1250’

781’

481’

4

2480’

1555’

978’

625’

391’

240’

6

1653’

1036’

625’

417’

260’

160’

8

1240’

777’

489’

313’

195’

120’

10

992’

622’

391’

250’

156’

96’

12

827’

518’

326’

208’

130’

80’

14

709’

444’

279’

179’

112’

69’

16

620’

389’

245’

156’

98’

60’

18

551’

345’

217’

139’

87’

53’

20

496’

311’

196’

125’

78’

48’

22

451’

283’

178’

114’

71’

44’

24

413’

259’

163’

104’

65’

40’

26

382’

239’

150’

96’

60’

37’

28

354’

222’

140’

89’

56’

34’

30

331’

207’

130’

83’

52’

32’

32

310’

194’

122’

78’

49’

30’

34

292’

183’

115’

74’

46’

28’

36

276’

173’

109’

69’

43’

27’

38

261’

164’

103’

66’

41’

25’

Number Of Clocks

40

248’

155’

98’

63’

39’

24’

Содержание V-2924A

Страница 1: ...NSIONS WEIGHT 5 30 L x 3 00 W x 1 10 D 13 46cm x 7 62cm x 2 79cm 0 9 lbs 0 41 kg FEATURES Valcom Digital Output Two clock ports independently programmable 24 mechanical clock types supported see code...

Страница 2: ...d Connector Port See Figure 1 for location Make connections to V CIO board if mechanical clocks are being used See Figure 2 for location CLOCK TYPE CODES Code Description Code Description 01 02 03 04...

Страница 3: ...onnector PC Programming Port located on Option Board J1 and J2 are located on the under side of the Clock Card Clock Control Card Port located on Clock Card DB15 Connector Remove and discard plate cov...

Страница 4: ...Couch C542014 through C452019 C452133 through 452145 Standard Electric Time AR2 Impulse 59th Minute ref Standard electric Time AR3A Impulse 60th Minute Ref Dukane 24A 24 Hour Correction Dukane 240 24...

Страница 5: ...14 15 NOT USED NOT USED DIGITAL OUT DIGITAL OUT NOT USED NOT USED CLK 1 K1 C CLK 1 K1 N O CLK 1 K4 C CLK 1 K4 N O CLK 2 K3 C CLK 2 K3 N O CLK 1 K2 C CLK 2 K2 N O GND BLACK WHITE RED GREEN ORANGE BLUE...

Страница 6: ...sically damaged 4 freight charges for the return of products to Valcom are prepaid 5 all units out of warranty are subject to a service charge The service charge will cover minor repairs major repairs...

Страница 7: ...7...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...12...

Страница 13: ...13...

Отзывы: