background image

ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS

MODEL V-2006A SIX ZONE INTEGRATED PAGE CONTROL

The Six Zone Integrated Page Control, Model V-2006A shall be a wall or shelf mounted, telephone compatible, six zone, one-way,

page control unit with integrated power supply and single/warble tone.  The unit shall be optionally loop start, ground start or contact closure
start and shall be capable of recognizing either DTMF tones or rotary pulse for dial selection of six individual zones, three groups containing
selected combinations of zones and all call.  The unit shall be programmable on a per zone basis for single  tone and interrupted warble
tone, inclusion in groups or all call, background music and with the installation of the optional plug-in talkback module, handsfree talkback
or one-way page operation.  System options shall include dial tone and ringback tone.  The unit shall have the ability to connect in tandem
with up to nine other units to provide a system wide all call.

The unit shall provide individual one-way low level outputs for each zone.  Individual handsfree talkback output shall also be

provided with the installation of the optional plug-in talkback module.   Group call and all call shall be one-way operation only.  Access of
specific zones shall not affect features programmed for other zones, i.e. background music shall mute only in the zone being paged while
other zones programmed for background music shall not be affected.

The unit shall provide two page access inputs.  One input shall be used for primary access of the unit.  The second input shall be

used for priority override page.  When priority override is accessed for page, it shall override any other page in progress and provide an
override tone indication.  The unit shall provide AGC circuitry for all voice page inputs.

In connection with a telephone system, the unit shall have the ability to provide loop current, the detection of which shall indicate

a request for service (in the loop start mode of operation).  Ground start operation shall be available as an optional mode of service request.
In connection with a telephone system page port, a "dry" tip and ring connection  with provision for contact closure start shall be provided.
A battery feed switch located on the unit shall enable or disable the loop current option of the tip and ring connections.  A second switch shall
select loop start or ground start service request options.

In connection with a telephone system supplying "A" lead control from each telephone, the unit shall also have the ability to provide

inhibit (speaker cancel) to  allow handset to handset "meet me" answer to a page without the paging system broadcasting the
conversation.

The unit shall have the ability to provide a single tone and an interrupted warble tone over page.  The single tone shall be activated

by a contact closure and shall follow the contact operation.  The interrupted warble tone shall be activated by a contact closure or a 90 Vac
ring signal.  The single tone shall have priority over the warble tone in the instance of coinciding activation.

The unit shall provide the ability to program features on a per zone basis using DTMF tones through a dedicated RJ11 jack.  Eight

LED's shall be provided for aid in programming and to check programming status of each zone.  Dip switches shall be provided for system
option programming.  The unit shall provide two auxiliary form C make-break contact closures.  One shall activate simultaneously with the
dial selection of zone six.  The other shall activate upon the detection of the "

*

" tone after any individual zone has been accessed and shall

time out after 2 seconds.  The detection of the "#" tone shall return dial access.  Dialing codes shall be 1 through 6 for individual zones, 7,
8, and 9 for group calls and 0 for all call.

The unit shall be equipped with a 50 pin male amphenol connector for input and output connections and an RJ11 jack for page tip

and ring input, override page tip and ring input, programming input, and all call expansion input/output connections. Screw terminals shall
be provided for auxiliary contact closure connections.  Volume controls shall be provided for tones, background music and all call.

The unit shall provide a three conductor grounded power cord with NEMA 15-5P type plug for AC input and shall provide auxiliary

-24 Vdc and GND outputs.  The outputs shall provide a total of 1.5 Amps of -24 Vdc for powering one-way amplified speakers or other
accessory devices.  The chassis shall be AC grounded.  The AC input shall be fuse protected at 1.0 Amp.  The unit shall be UL Listed.

The unit shall have a power consumption of 2 Amp at 120 Vac.  Both page inputs shall have an impedance of  600 Ohms.  Music

source impedance shall be 8 to 600 ohms.  Music input level shall be -10 dBm nominal. Low level output impedance shall be 8 ohms.   Low
level output level shall be -10 dBm nominal.  Auxiliary relay contacts shall be rated at 2 Amps at 30 Vdc.  Operating temperature shall be +32
to 104 °F (0 to + 40 °C).  Operating humidity level shall be 0% to 85% non-condensing.

An optional Plug-in Talkback Module, Model V-9956, shall be available separately.  It shall be a plug-in circuit board compatible

with the V-2006A to field upgrade it for handsfree talkback capability.  It shall provide phone to speaker, speaker to phone, tone, background
music and page and all call volume controls.  System options shall include alert tone and repeated alert tone.  Output impedance shall be
45 ohms.  Output level shall be 1 watt nominal.  Voice switch sensitivity shall be -26 dBm.  A separate unit, the Six Zone Integrated Talkback
Page Control, Model V-2006AHF, shall be available with the talkback module already installed.

The Battery Back-up Supply, Model VPB-260, shall be available separately.  It shall provide a polarized molex connector

compatible with the molex connector on the V-2006A.  In the even to power failure, it shall provide power back-up to the V-2006A and any
additional equipment powered by the DC outputs on the V-2006A.

The housing of the unit shall be constructed of gray painted aluminum alloy.  The maximum dimensions shall be 10.25"

(26.04 cm) H x 13.0" (33.02 cm) W x 2.69" (6.83 cm) D. Shipping Weight shall be approximately  9.0 lbs (4.09 kg).

5614 Hollins Road      Roanoke, Virginia  24019      Phone:  540-563-2000      Fax:  540-362-9800

E-Mail:  [email protected]               www.valcom.com

Отзывы: