INSTALLATION

Input Access / Switch Settings

A four position slide switch is used to select the 
telephone access mode. 

(LS) Loop Start

Used with a Loop Start Trunk Port of a PBX or 
Key System, or a dedicated phone set.  

(GS/LSS) 
Ground Start/Loop Start Supervised

Access from a PBX Ground Start Trunk Port. 
In this mode, the PBX ground 

must

 be con-

nected to pin 1 of the 20-pin connector on the 

PagePal

®

 or pin 2 of the RJ11 connector on 

the PagePal.

In Loop

 

Start

 

Supervised

 

mode, pin 7 of the 

PagePal 

must

 be connected to pin 1 on the 

20-pin connector to allow supervision of the 
Loop Start Trunk Port. The PagePal will super-
vise the connection, and will automatically dis-
connect the line if no voice is detected on the 
line for 20 seconds or if the line remains active 
(off hook) for more than one minute.

(SA) Station Access

Used with a standard (ANALOG) station port 
on a CENTREX, PBX, Key System, or Central 
Office subscriber line. Use a two-wire RJ11 
cable in this mode.  The PagePal receives talk 
battery and ring voltage from the host system.

(DL) Dry Loop

Interfaces with the Page Port of a PBX or Key 
System, or an Auxiliary port of a PBX.  This 
input shall respond to resistances from 0 to 1K 
Ohms and will ignore resistance greater than 
10K Ohms.  Use a four-wire RJ11 cable in this 
mode.  Dry Loop is a four wire connection. 
Pins 2 and 5 of the RJ11 are intended to inter-
face with the control leads of the host system, 
while pins 3 and 4 connect to Tip and Ring, as 
usual.  See Table 2 for pinout descriptions.

Main Output

Adjusts level of output.  Full clockwise rotation 
provides 14 dBm gain.

Set the Main Output level first using telephone 
input, then adjust Attendant and Music Inputs for 
an appropriate relative level.

Attendant Input

Adjusts level of Attendant Input relative to the 
Telephone Input.  Adjustment range is from 0 dBm 
to less than -30 dBm.

Music Input

Adjusts level of Music Input relative to the Tele-
phone Input.  Adjustment range is from 0 dBm to 
less than -30 dBm.

TECHNICAL ASSISTANCE

When calling, have a VOM and a telephone test 
set available and call from the job site.  Call (540) 
427-3900 and ask for PagePac Technical Sup-
port, or call (540) 427-6000 for Valcom 24-hour 
Automated Support or visit our websites at http://
www.pagepac.com and www.valcom.com.

Should repairs be necessary, attach a tag to the 
unit clearly stating company name, address, 
phone number, contact person, and the nature of 
the problem.  Send the unit to:

PagePac

®

 Repair Dept.

Valcom, Inc.

5614 Hollins Road

Roanoke, VA  24019-5056

Technical Manuals Online! - http://www.tech-man.com

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Отзывы: