background image

 

                                                   3                                                              947727     

Network Connection 

The VIP-431-A-IC has one RJ-45 network 
connector on the rear panel.  Use a standard patch 
cable to connect the VIP-431-A-IC to an Ethernet 
switch. (See Figure 2) 


 

 
 
 
 
 
 
 
 
 
 
 
 
 
          

Figure 2.  Ethernet Connection

Call Switch Connection  

The Talkback IP Speaker provides a call switch 
input via screw terminal connections. See  
Figure 3 for detailed connections.  
 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to 
up to 40 Valcom Self Amplified Speakers in order to 
provide additional sound reinforcement in an area.

 

 
Mute Out Connection 

Not used with InformaCast systems. 

 

LED Connection 

LED (+) and (-) is a current limited output designed 
to illuminate an optional LED. The LED is intended 
to provide visual indication of call progress.  The 
LED illumination will flash when the call switch is 
pressed and will continue to flash until the call is 
answered.  The LED illumination will be solid when 
a connection to the unit is established. 
 

Setup 

The VIP-431-A-IC will automatically acquire an IP 
address (using DHCP) and connect to the 
InformaCast server when connected to the network 
and powered up.  Time synchronization is provided 
by the InformaCast server.  Information specific to 
your application will need to be programmed into 
the InformaCast server. Refer to the InformaCast 
documentation for further information. 

 

 
 

 

Figure 3.  Connections 

 

 
 