3 947727
Network Connection
The VIP-431-A-IC has one RJ-45 network
connector on the rear panel. Use a standard patch
cable to connect the VIP-431-A-IC to an Ethernet
switch. (See Figure 2)
.
Figure 2. Ethernet Connection
Call Switch Connection
The Talkback IP Speaker provides a call switch
input via screw terminal connections. See
Figure 3 for detailed connections.
-10 dB Line Level Out Connection
The -10dBm Line Level Out may be connected to
up to 40 Valcom Self Amplified Speakers in order to
provide additional sound reinforcement in an area.
Mute Out Connection
Not used with InformaCast systems.
LED Connection
LED (+) and (-) is a current limited output designed
to illuminate an optional LED. The LED is intended
to provide visual indication of call progress. The
LED illumination will flash when the call switch is
pressed and will continue to flash until the call is
answered. The LED illumination will be solid when
a connection to the unit is established.
Setup
The VIP-431-A-IC will automatically acquire an IP
address (using DHCP) and connect to the
InformaCast server when connected to the network
and powered up. Time synchronization is provided
by the InformaCast server. Information specific to
your application will need to be programmed into
the InformaCast server. Refer to the InformaCast
documentation for further information.
Figure 3. Connections