Valco baby Heat Rite 60 Скачать руководство пользователя страница 3

WARNING

Fire and Explosion Hazard

Not for home or recreational vehicle use.

Installation of this heater in a home or

recreational vehicle may result in a fire or

explosion.

Fire or explosions can cause property

damage or loss of life.

FOR YOUR SAFETY

If you smell gas:

Open windows.

Don't touch electrical switches.

Extinguish any open flame.

Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any

other appliance.

WARNING

Fire and Explosion Hazard

Keep solid combustibles a safe distance

away from the heater.

Solid combustibles include wood or paper

products, feathers, straw, and dust. 

Do not use the heater in spaces which

contain or may contain volatile or airborne

combustibles.

Volatile or airborne combustibles include

gasoline, solvents, paint thinner, dust

particles or unknown chemicals. 

Failure to follow these instructions may

result in a fire or explosion.

Fire or explosions can lead to property

damage, personal injury or loss of life.

GENERAL  HAZARD  WARNING

Failure to comply with the precautions and instructions provided with this heater, can result in:

— Death

— Serious bodily injury or burns

— Property damage or loss from fire or explosion

— Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning 

— Electrical shock

Read this Owner’s Manual before installing or using this heater.

Only properly-trained service people should repair or install this heater.

Save this Owner’s Manual for future use and reference.

Owner’s Manuals and replacement labels are available at no charge.  For assistance, contact

VAL-CO at 419-678-8731.

WARNING

Proper gas supply pressure must be provided to the inlet of the heater.

Refer to the heater’s dataplate for proper gas supply pressure.

Gas pressure in excess of the maximum inlet pressure specified at the heater inlet can cause

fires or explosions.

Fires or explosions can lead to serious injury, death, building damage or loss of livestock.

Gas pressure below the minimum inlet pressure specified at the heater inlet may cause

improper combustion.

Improper combustion can lead to asphyxiation or carbon monoxide poisoning and therefore

serious injury or death to humans and livestock.

2

CONSIGNES DE SECURITE

Si vous sentez une odeur de gaz:

Ouvrez le fenetres.

Ne touchez pas aux interrupteurs

electriques.

Eteignez toute flamme nue.

Contactez immediatement votre

compangie de gaz.

CONSIGNES DE SECURITE

Ill es interdit d'utiliser des liquides

inflammables ou degageant des vapeurs

inflammables, a proximite de tout appareil

fonctionnant au gaz.

Содержание Heat Rite 60

Страница 1: ...at VAL CO thank you for your confidence in our products and welcome any suggestions or comments you may have call us at 419 678 8731 Owner s Manual and Instructions Agricultural Animal Confinement Bui...

Страница 2: ...gricultural confinement building heater CAN 1 2 20 and is listed and approved for Canadian installations as a gas fired brooder CAN 1 2 21 Gas Fired Appliances for Outdoor Installation CAN CGA 2 17 Ga...

Страница 3: ...perty damage or loss from fire or explosion Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning Electrical shock Read this Owner s Manual before installing or using this heate...

Страница 4: ...VAL CO distributor or VAL CO for assistance or if you have any questions about the use of the equipment or its application VAL CO has a policy of continuous product improvement It reserves the right t...

Страница 5: ...ural Gas Gas Gas Gas M Mo od de el l Ventilation Air Required to Support Combustion Burner Manifold Pressure Electrical Supply Volts Hz Phase Amp Draw Dimensions L x W x H in inches Minimum Safe Dista...

Страница 6: ...ing Symptoms of improper combustion affecting livestock can be disease lower feed conversion or death Asphyxiation Hazard Some p people c cannot s smell w well S Some p people c cannot smell t the o o...

Страница 7: ...erior of the heater and it s components After external washdown do not operate this heater until it is completely dry In any event do not operate the heater for at least one hour after external washdo...

Страница 8: ...within 6 ft of the heater it serves 9 Check all connections for gas leaks using approved gas leak detectors Gas leak testing is performed as follows Check all pipe connections hose connections fitting...

Страница 9: ...ided in accordance with national provincial local codes of CAN CGA B149 if local code requirements do not exist CAN CGA B149 requires the building have ventilation of not less than 3 cfm per 1 000 BTU...

Страница 10: ...and is hanging level Check crosswise and lengthwise 4 See Fig 3 for typical indoor installation In any animal confinement building consideration must be given to making sure the heater is located awa...

Страница 11: ...thermostat to the heater Failure to follow this warning can result in electrical shock leading to personal injury or death THERMOSTAT INSTALLATION SEDIMENT TRAP ASSEMBLY NIPPLE HOSE ADAPTER TEE NIPPL...

Страница 12: ...ll manual fuel supply valves and check for gas leaks using approved leak detectors 2 Open the cover of the gas control valve enclosure 3 The gas control valve incorporates a manual gas shut off featur...

Страница 13: ...ther minimum heat or maximum heat When the throttle valve handle is parallel to the gas flow the valve is completely open to deliver maximum heat output Refer to Fig 7 FIG 7 The throttle valve may be...

Страница 14: ...enturi ports and the throat of the casting are free of dust accumulation and the area between the heat chamber top and inside case is also free of dust c When washing with water observe and obey the W...

Страница 15: ...by disconnecting the leads at the component and placing a jumper connecting the leads together Reconnect the electrical supply and open fuel supply valves If the heater lights the component is defecti...

Страница 16: ...t to blower housing 2 Turn the switch assembly 90 so the paddle on the switch arm can be pulled through the oblong hole on side of fan housing 3 The replacement switch will be pre assembled to its mou...

Страница 17: ...ve It should only be replaced with the PSI part number referenced in the parts listing of this owner s manual When threading the thermocouple s connector nut back into the gas control valve thread the...

Страница 18: ...valve to the heater inlet 3 Open the control box 4 Brush or blow off any dust and dirt on or in the vicinity of the gas control valve B Gauge I Installation 1 Remove the inlet and outlet pressure tap...

Страница 19: ...h terminals to verify contacts have opened 5 Allow the switch cool down before firmly pressing the red reset button on the switch 6 Check for electrical continuity across the switch terminals to make...

Страница 20: ...f explanation of each problem Start at the diamond closest to the identified problem and proceed with each step performing whatever tests are suggested After each step or test the guide will direct th...

Страница 21: ...he pilot control button fully depressed Replace pilot orifice Is there air in the gas line No No Fully depress the pilot button No No No Yes Depress pilot button to bleed off the air until pilot light...

Страница 22: ...an with compressed air Do not use pointed instruments Replace pilot orifice if necessary Is pilot assembly including orifice clean Are pilot line or gas supply hose partially plugged Yes Remove and cl...

Страница 23: ...ft Reset switch Determine cause of high limit tripping See Problem 7 Yes Clean out debris Check electrical connections to high limit switch and to control valve and check wires for continuity Check fo...

Страница 24: ...ed to motor Do thermostat contacts open and close Perform continuity check Provide proper voltage See heater dataplate Check circuit breaker in electrical system Set thermostat above room temperature...

Страница 25: ...l ight will n n ot stay l l it when m m ain burner a a nd motor a a re operating Have you checked for proper fuel use and inlet gas pressure Yes No Check for proper pressure Make sure proper fuel is b...

Страница 26: ...sed proper pressure or for liquid propane in the line Check building electrical system Repair as necessary See heater dataplate for correct voltage Is proper voltage being supplied to motor Is heater...

Страница 27: ...f o o f burner Has gas pressure been checked Yes No Yes Are there blockages in burner casting burner orifice or primary air inlets of casting Clean with compressed air Check for proper pressure to inl...

Страница 28: ...ermocouples use a retainer clip to secure the thermocouple into the pilot bracket Make sure the thermocouple is pushed up completely into the hole so clip on thermocouple holds it securely within the...

Страница 29: ...RMOSTAT NEUTRAL GROUND MOTOR HIGH LIMIT SWITCH GAS CONTROL VALVE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK GREEN BLACK BLACK BLACK OR RED BLACK OR RED AIR PROVING SWITCH NOT SUPPLIED ON SOME MOD...

Страница 30: ...rlocked with the heater to prevent operation of the heater unless the ventilation air flow is proven by an air flow proving device The exhaust fan CFM output must equal or exceed the ventilation air t...

Страница 31: ...he main burner and heating the thermocouple Pilot Safety Control Valve A gas control valve which is held open by electrical power supplied by a pilot generator and which closes automatically to shut o...

Страница 32: ...Parts Identification PARTS SCHEMATIC 24 22 27 23 26 25 14 17 18 15 8 10 5 4 13 11 12 3 6 9 16 20 19 2 7 21 1 2 31...

Страница 33: ...t 03420 16 Orifice Burner Propane 81017 81062 Natural Gas 81018 81149 17 Valve Throttle Propane 81678 81486 Natural Gas 81679 20144 18 Base Top 81191 80445 19 Base Bottom 81192 80582 20 Terminal Strip...

Страница 34: ...e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than the date code but within 1...

Отзывы: