VAL6 KBE5S & KBE5L  Trouble Shooting

No.

Possible Cause

How to check

Result

Remedy

16

Circuit board (Burner
control) is defective

Measure voltage at input
side of transformer
connector (CN 7)

If  power source is
normal and tester reads
0V at input side, circuit
board is defective

Replace circuit
board (burner
control)

17

Terminals of control
device is uncoupled

Check whether the
terminals for control
device are connected
firmly

Firmly connect
terminals on control
device

18

Direct sunlight hits
flame monitor

If it starts, sunlight is
detected by flame
monitor

Move disk away
from direct sunlight
or bright light source

19

Circuit board (Burner
control) is defective

If it doesn't start, circuit
board is defective

Replace a circuit
board

20

Over voltage is being
detected

Change the power source
or confirm whether the
voltage of power source
or generator is correct

Find a cause of over
voltage and take
away them

21

Combustion fan
connector is loose
connection

Plug combustion fan
connector (CN 13) again,
and then turn on

If it works normally,
combustion fan
connector fails on contact

Plug connector
(CN13) firmly

22

Combustion fan motor
is clogged

Try to rotate a vane by
hand (*Be sure to plug
off beforehand)

If a vane isn't rotated
smoothly or completely,
the combustion fan is
clogged

Replace a
combustion fan

23

Combustion fan and/or
circuit board (Burner
control) is defective

Refer to above #21 & 22 There is no cause in #21

& 22, combustion fan
and/or circuit board are
defective

Replace a
combustion fan
and/or circuit board

  Overvoltage lamp is not lit (Operation lamp and misfire lamp are lit)

Unplug flame monitor
connector (CN11), then
turn on switch

  All three(operation, misfire, over voltage) lamps are lit

Combustion fan does not run

Standard: AC120V (white-red)

  Misfire lamp is not lit (Only operation lamp is lit)

4

Содержание KBE5L

Страница 1: ...VAL6 Infrared Heater Maintenance Manual KBE5S KBE5L 2 step...

Страница 2: ...Wiring Diagram of Burner Control KBE5S KBE5L 2 step Sequence Time Chart Operation Switch Solenoid Pump Fan Igniter ON OFF 180 sec 5 sec within 10 sec 10 sec post ignition ignition...

Страница 3: ...uel pump is short circuited 7 turning on the switch YES NO YES NO Power source is not supplied 8 Fuse blows out 9 Power cord is disconnected 10 Power sorce connector is loose connection 11 Transformer...

Страница 4: ...d burner 23 control is defective YES NO Ignition transformer connector or high voltage 24 cord is loose connection Electrode is defective 25 Ignition transformer is defective 26 crack in high voltage...

Страница 5: ...e is clogged 38 Fuel is contaminated with water 39 NO YES NO YES Lens of flame monitor is dirty or dusty 40 Poor lighting is detected by flame monitor 41 Flame monitor connector is loose connection 42...

Страница 6: ...defective 52 NO YES YES NO Fuel viscosity is increasing 53 Black White Fuel viscosity is increasing 54 Nozzle is clogged 55 YES NO gives off black Combustion air is insufficient 56 smoke 57 Oxygen for...

Страница 7: ...ustion air is insufficient 62 Oxygen for combustion is low because of high 63 Normal Operation Smell of fuel comes out Flame bounces out from the disk The unburnt component may come out under the temp...

Страница 8: ...it board then measure coil resistance values of two leads If either lead shows the transformer is short circuited Replace a transformer Without circuit tester Disconnect transformer connector CN 7 fro...

Страница 9: ...nce between terminals If the value shows the ignition coils is short circuited Replace an ignition transformer Without circuit tester Disconnect ignition connector CN 4 and then start operation If the...

Страница 10: ...power source connector fails on contact Plug in connector CN 1 firmly 12 Transformer connector is loose connection Plug in transformer connector CN 7 again and then turn on If it works normally transf...

Страница 11: ...whether the voltage of power source or generator is correct Find a cause of over voltage and take away them 21 Combustion fan connector is loose connection Plug combustion fan connector CN 13 again an...

Страница 12: ...p connector CN6 again and then turn on If it works normally fuel pump connector fails on contact Plug connector CN6 firmly 29 Fuel pump is defective If the value shows standard voltage the pump is def...

Страница 13: ...etone 36 Fuel pump is clogged or defective Loose the brass nut then switch on and check whether fuel comes out place a pan under the pump If no fuel is pump up or fuel is not flowing at least 2 high t...

Страница 14: ...flame properly Clean the lens of flame monitor with soft cloth 41 Poor lighting is detected by flame monitor Remove a burner and check whether the whirl vane and inside of draft tube are clear or not...

Страница 15: ...is clogged Check if air intake of fuel gauge is clogged with dust If air intake of fuel gauge is clogged fuel flow is insufficient by pressure drop in fuel tank Clear an air intake of fuel gauge 48 O...

Страница 16: ...sed fuel is not sprayed normally from the nozzle because fuel viscosity is increased by low ambient temperature Warming up fuel refueling winter fuel or mixing kerosene with fuel in order to decrease...

Страница 17: ...l scale 3 Check whether applied voltage is normal Standard 120V 10 If applied voltage is lower than 108V imperfect combustion by decreasing of combustion fan rotation speed occurs Find a cause s of lo...

Страница 18: ...a combustion fan and or circuit board Check whether vanes of combustion fan are dusty If vanes are dusty imperfect combustion is occurs by low oxygen Clean a vanes of combustion fan Check whether air...

Страница 19: ...12 VAL6 KBE5S KBE5L Trouble Shooting No Possible Cause How to check Result Remedy 10 0 5mm 8 0 5mm 2 4 0 5mm Electrode Nozzle Electrode Drawing 12...

Страница 20: ...zle Make sure that the pump turns on you can feel and hear the vibration This will occur approximately 5 seconds after the switch has been turned on Make sure that the electrode is sparking You will h...

Страница 21: ...ition Voltage Power code CN1 Black White AC 120V 10 Red White input AC 120V 10 Purple Purple output about AC 15V Igniter CN4 Black Black input AC 120V 10 60Hz AC 120V 10 50Hz Fan motor CN3 Gray Gray a...

Страница 22: ...you will measure from burner control Turn on the circuit tester and set AC voltage range Insert the lead head of resistor to connector lead wire side and measure resistance Turn on the circuit tester...

Страница 23: ...p fuel gauge Object Serial Number from 01Q 030000 2003 2004 model If air intake of fuel gauge is clogged clean it up Open a screw cap and take out a fuse Take out the burner control and point the lead...

Страница 24: ...an altitude higher than 3 000 ft you need to expand combustion air inlet opening Unfasten a knob and expand combustion air inlet opening Fasten a knob of combustion fan and put a burner cover back Yo...

Страница 25: ...minate the dirt or water from the fuel tank Remove the fuel cap take out the tank inlet Later on please remove with wrench the filter and insert a handy suction pump into drain bolt and tilt the fuel...

Страница 26: ...eaner or wipe with a soft cloth etc Periodic Inspection The heater must be checked if used for a long time Please ask your dealer to inspect the heater every two 2 seasons How to connect the Control d...

Отзывы: