User’s Guide ______________________________________________________________________
118 _________________________________________________________________ M210906EN-C
Setting Fields
The parameter order is shown in the following table:
[R]
=
Parameter selection: This field consists of 16 bits
defining the precipitation parameters included in the
data messages. The bit value 0 disables and the bit
value 1 enables the parameter.
The bits 1-8 determine the
parameters included in the
messages obtained with the
following commands:
-
ASCII:
aR3 and ar3
-
NMEA 0183:
$--WIQ,XDR*hh
-
SDI-12:
aM3, aMC3, aC3,
aCC3
-
SDI-12 continuous:
aR3 and
ar3
1st bit (most left)
Rc Rain amount
2nd bit
Rd Rain duration
3rd bit
Ri Rain intensity
4th bit
Hc Hail amount
5th bit
Hd Hail duration
6th bit
Hi Hail intensity
7th bit
Rp Rain peak
8th bit
Hp Hail peak
&
delimiter
The bits 9-16 determine the
precipitation parameters
included in the composite
data messages obtained
with the following
commands:
-
ASCII:
aR0 and ar0
-
NMEA 0183:
aR0, ar0
-
SDI-12:
aM, aMC, aC, aCC
-
SDI-12 continuous:
aR and
aRC
9th bit
Rc Rain amount
10th bit
Rd Rain duration
11th bit
Ri Rain intensity
12th bit
Hc Hail amount
13th bit
Hd Hail duration
14th bit
Hi Hail intensity
15th bit
Rp Rain peak
16th bit (most right)
Hp Hail peak
[I]
=
Update interval: 1 ... 3600 seconds. This interval is
valid only if the
[M]
field is = T
[U]
=
Precipitation units:
M
= metric (accumulated rainfall in mm, Rain
duration in s, Rain intensity in mm/h)
I
= imperial (the corresponding parameters in units
in, s, in/h)
Содержание WXT520
Страница 1: ...USER S GUIDE Vaisala Weather Transmitter WXT520 M210906EN C...
Страница 171: ...www vaisala com M210906EN...