6.
Enter the line cable through the left side cable gland and make the wiring to the line terminals.
For best shielding from RF interference, bend the output cable shield over the plastic sleeve and
O-ring and tighten the line cable gland carefully.
7.
Enter the device cable through the right side cable gland and make the wiring to the device
terminals as shown below. Carefully tighten the device cable gland.
8.
Reattach the enclosure cover with the 4 plastic screws.
9.
If the mast (or its surface or base) is poorly conductive, use a grounding wire. Connect the wire
end to the crimp connector provided in the plastic bag. Fix the connector with the M5 nut and
washer to the grounding screw at the enclosure's rear upper left corner.
To minimize surge induction to the cable, make sure the device cable is short.
Ground the unit through the mast or with a 16 mm2 (AWG 5) copper wire from the grounding
screw to true earth (lightning ground).
CAUTION!
Wiring WSP150
In other products, wire colors and signal names may differ.
Figure 2 Wiring with RS-485