![Vaisala WAT12 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/vaisala/wat12/wat12_user-manual_3470431014.webp)
7. Attach the unit on the top of a pole mast with the mounting clamp as shown in
WAT12 on top of pole mast (page 23)
8. Mount the sensors onto the cross arm.
Mounting wind sensor to WAT12 (page 25)
and
Vaisala Anemometer WAA151 User
Guide
and
Vaisala Wind Vane WAV151 User Guide
.
9. Before erecting the mast, align the cross arm as instructed in
3.3 Jumper settings
The loop current can be selected with the onboard jumper plugs. Several output ranges, such
as 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 mA, 2 ... 10 mA, 0 … 5 mA, and 1 … 5 mA, are available as user-
configurable options, each with factory-adjusted zero and span levels. The voltage-mode
signals are easily obtained by connecting a suitable resistor across the readout device's
terminals. Signal full scale options are also available. For example, a directional scale of 540°
(0-360-180°), which is convenient for analog panel meters or chart recorders, can be chosen
to prevent the needle or pen from oscillating across the scale with northerly winds.
Figure 3 Location of jumpers
1
X4: Test and operation
2
X5: Output zero
3
X7: Scaling together with X6
4
X8: Output span
5
X6: Scaling together with X7
WAT12 User Guide
M210309EN-B
12
Содержание WAT12
Страница 1: ...M210309EN B User Guide Analog Wind Transmitter WAT12...
Страница 6: ...WAT12 User Guide M210309EN B 4...
Страница 23: ...Figure 15 Wiring with WHP151 mains power supply Chapter 3 Installation 21...
Страница 24: ...Figure 16 Wiring with WHP25 mains power supply and WA25 sensors WAT12 User Guide M210309EN B 22...
Страница 34: ......
Страница 36: ......
Страница 37: ......
Страница 38: ...www vaisala com...