![Vaisala AWS310-SITE Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/vaisala/aws310-site/aws310-site_integration-manual_3200537041.webp)
Keep the cut within the given dimensions. The wider the slot, the more
filling material is needed and the higher the risk of cracking. A wide slot may also affect
the thermal characteristics of the road or runway surface and cause poor thermal contact
to the road or the runway.
CAUTION!
1. Mark the intended line of the cut in the road or runway keeping it as straight as
possible.
2. Use a diamond saw to cut a slot for the cable from the sensor slot to the edge of the
road or runway.
3. Cut a slot for the sensor at the end of the cable slot.
The following figure shows the cut lines for floor saw (left) and electric breaker (right).
4. Make sure that the sensor fits in the slot with 5 mm (0.20 in) excess around.
5. Cut a hole and install DTS12G, if needed.
Chapter 4 – Installation
39
Содержание AWS310-SITE
Страница 1: ...M212071EN C RWCC Integration Guide Vaisala Automatic Weather Station AWS310 SITE...
Страница 43: ...2 Drill a hole through the cable slot 1 300 11 81 12 15 0 47 0 59 mm in Chapter 4 Installation 41...