Installation instructions VRT 392f 0020044239_01
8
6 Initial commissioning
Initial condition:
The controller VRT 392f and the radio receiver unit are
installed correctly.
The appliance is switched on and ready for operation.
h
Note
To ensure the most effective control by the
VRT 392f the position of both rotary knobs on
the appliance must be observed:
–
Top rotary knob (outlet/storage temperature
of hot water) at maximum setting (limit stop
in clockwise direction).
–
Bottom rotary knob (feed temperature of
heating) at maximum required feed
temperature.
The operating concept of the VRT 392 is described in
Section 4.3 of the operating manual.
6.1
Installation assistant
When commissioning for the first time you will be
supported by the installation assistant. The installation
assistant recognises the connected components of the
heating system.
Up to six pages are available in the display (A1 to A6)
depending on the configuration of the heating system.
The most important parameters of the heating system
can be entered via the installation assistant.
The installation assistant starts with display screen A1,
language selection.
Select the language in accordance with the
operator control concept (operating instructions
Section 4.3).
Turn the left-hand dial clockwise by one indexing
position to display additional screen A1.
Installation assistant
RF Link
A1
Controller
10
Teach in
OFF
>Select mode
Fig. 6.1 Installation assistant, screen A1
You can read off or check the quality of the radio signal
path between the controller or wireless outdoor sensor
and radio receiver unit here.
The quality of the wireless data communication for
outdoor sensors and controllers is represented by a
number between 0 and 10.
0:
no reception
1:
poor quality
10:
excellent quality
h
Note
If this value is less than 3 you will have to
change the installation location of the
controller or radio receiver unit. A description
of the installation of the radio receiver unit on
the wall is provided in Section 4.4.1.
Note
The range of radio transmission within buildings
is largely dependent on the local conditions
(e.g. the nature of the building). This means
that a range of 25 m within the building cannot
always be guaranteed. A range of more than
100 m can be achieved outside enclosed spaces
(free field).
The quality displayed is updated automatically as soon
as changes are made.
h
Note
The "teach-in" display is only required for
teaching in components in the radio network
following the replacement of parts.
Turn the left-hand dial clockwise by one indexing
position in order to display page A2.
Installation assistant
System configuration
A 2
Cylinder
active
> select
Fig. 6.2 Installation assistant screen A2
The configuration of the heating system is shown in
display screen A2.
For the cylinder (storage), you can choose between
active and inactive.
6 Initial commissioning